{"product_id":"omron-cs1w-ia111-input-module","title":"Omron CS1W-IA111 Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCS1W-IA111\u003c\/strong\u003e is an \u003cstrong\u003eAC\/DC Input Module\u003c\/strong\u003e designed for Omron’s high-performance \u003cstrong\u003eCS1 series PLC\u003c\/strong\u003e system. This unit provides 16 digital input points, allowing the PLC to monitor external signal devices such as limit switches, sensors, or pushbuttons operating within a 100 to 120 VAC\/VDC voltage range.\u003c\/p\u003e\n\u003cp\u003eAs part of the \u003cstrong\u003eCS1 Basic I\/O\u003c\/strong\u003e classification, this module is built for industrial durability and reliable data acquisition. It features a removable terminal block, which simplifies installation and replacement during system maintenance without requiring the rewiring of individual signal cables. It is a fundamental component for building robust control systems in manufacturing, processing, and automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Omron CS1 Basic I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Points:\u003c\/strong\u003e 16 points for multi-channel signal monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e Supports 100 to 120 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEase of Maintenance:\u003c\/strong\u003e Features a removable terminal block for efficient field service\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Designed for seamless mounting and communication within the CS1 PLC rack architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Low current consumption (0.11 A from the 5V system)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring 110V industrial control circuits and safety relays\u003c\/li\u003e\n\u003cli\u003eSignal acquisition from limit switches and proximity sensors in large-scale machinery\u003c\/li\u003e\n\u003cli\u003eFeedback loops for panel-mounted operator pushbuttons and status indicators\u003c\/li\u003e\n\u003cli\u003eInterfacing with standard AC industrial field devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCS1W-IA111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 120 VAC\/VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOccupancy\u003c\/td\u003e\n\u003ctd\u003e1 CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.11 A (5V system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module slides directly into the CS1 PLC backplane. Ensure the module is securely locked into the rack to maintain stable electrical contact with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire gauges for the terminal block. Since this module handles 100-120V, ensure that all safety protocols for high-voltage wiring are followed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e While the module is isolated, ensure the PLC rack itself is connected to a high-quality chassis ground to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Always power down the PLC rack before inserting or removing the I\/O module to prevent potential electrical arcing or damage to the module pins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077936734571,"sku":"CS1W-IA111","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CS1W-IA111-fnzz0gtzbnw.png?v=1775733699","url":"https:\/\/www.plcprotech.com\/products\/omron-cs1w-ia111-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}