{"product_id":"omron-e5cc-rx0asm-000-e5cc-digital-temperature-controller","title":"Omron E5CC-RX0ASM-000 E5CC Digital Temperature Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eManaging precise thermal profiles in demanding processing environments is the primary function of the \u003cstrong\u003eOmron E5CC-RX0ASM-000\u003c\/strong\u003e digital temperature controller. Operating with an ultra-fast \u003cstrong\u003e50 ms input sampling period\u003c\/strong\u003e, this instrument executes real-time control loop adjustments to stabilize dynamic systems. It features a high-contrast dual display for clear visibility of Process Value (PV) and Set Value (SV) parameters, making it an essential component for critical industrial machinery. Designed with a shallow housing depth to minimize panel space requirements, this unit handles universal thermal inputs with high accuracy, ensuring reliable operational repeatability.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Sampling:\u003c\/strong\u003e Rapid 50 ms sampling cycle captures micro-thermal deviations instantly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Input Compatibility:\u003c\/strong\u003e Direct integration with thermocouples, platinum resistance thermometers, and standard analog linear signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Housing Profile:\u003c\/strong\u003e Panel-mount configuration requires minimal enclosure depth, maximizing internal wiring space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Status Display:\u003c\/strong\u003e Clear digital readouts provide real-time diagnostic and process feedback directly on the front interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003ePackaging machinery sealing-jaw thermal regulation.\u003c\/li\u003e\n  \u003cli\u003ePlastics extrusion and injection molding barrel zone controls.\u003c\/li\u003e\n  \u003cli\u003eIndustrial heat-treatment chambers and laboratory ovens.\u003c\/li\u003e\n  \u003cli\u003eFood pasteurization and high-accuracy liquid processing operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ SKU\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eE5CC-RX0ASM-000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eE5CC Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDigital Temperature Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInput Sampling Period\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e50 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eThermocouple Accuracy\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e(plus\/minus 0.3% of PV or plus\/minus 1 degC, whichever is greater) plus\/minus 1 digit max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eRTD Input Accuracy\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e(plus\/minus 0.2% of PV or plus\/minus 0.8 degC, whichever is greater) plus\/minus 1 digit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eAnalog Input Accuracy\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eplus\/minus 0.2% FS plus\/minus 1 digit max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCurrent Transformer (CT) Input Accuracy\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eplus\/minus 5% FS plus\/minus 1 digit max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTransfer Output Accuracy\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eplus\/minus 0.3% FS max\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eRemote SP Input Accuracy\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eplus\/minus 0.2% FS plus\/minus 1 digit max\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.13 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen replacing older legacy controllers such as the Omron E5CN series, verify depth clearances. The E5CC series features a shallow 60 mm body behind the panel, which is significantly smaller than previous configurations. Program parameters can be migrated seamlessly via CX-Thermo software, eliminating the need for manual code translation.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause of the rapid 50 ms sampling rate, high-gain PID configurations may exhibit oscillations if there is physical thermal lag between the heating element and the sensor probe. Running the auto-tuning sequence at normal system operating temperatures rather than cold-starting the process minimizes integral windup risk.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThermocouple extension wires must be routed completely isolated from high-voltage AC lines to avoid electromagnetic interference. Ensure that rear terminal connection screws are torqued exactly to manufacturer specifications to maintain solid contact points, as loose connections will induce cold-junction compensation measurement errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"font-weight: bold; color: #9b2c2c; margin: 0 0 0.5rem 0;\"\u003eCRITICAL SAFETY WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eIsolate and lock out all electrical power sources supplying the control cabinet prior to beginning hardware installation. Ensure the system has fully discharged any capacitive voltage to prevent electrical shock. Verify physical layout dimensions and panel cutouts prior to securing the controller brackets.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eInsert the controller housing through the standard DIN panel cutout from the front face.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eSlide the mounting fixture along the housing body from the rear of the panel until it locks tightly against the panel inner wall.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eTerminate field power and sensor wiring to the rear terminals using insulated crimp terminals, ensuring clean wire separation.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077936046443,"sku":"E5CC-RX0ASM-000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e5cc-rx0asm-000-k03pcrvktp3.png?v=1775733750","url":"https:\/\/www.plcprotech.com\/products\/omron-e5cc-rx0asm-000-e5cc-digital-temperature-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}