{"product_id":"omron-ns5-mq11b-v2-ns-series-programmable-terminal","title":"Omron NS5-MQ11B-V2 NS Series Programmable Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for direct machine-level operator interface, the \u003cstrong\u003eOmron NS5-MQ11B-V2\u003c\/strong\u003e integrates a high-luminance monochrome display with robust field communications to manage automated processes within industrial environments. Featuring a 5.7-inch screen with an analog resistive touch panel, this programmable terminal provides a cost-effective, high-reliability interface for system configurations utilizing Omron SYSMAC controllers. With dual onboard RS-232C ports and integrated 10\/100Base-T Ethernet, it allows seamless integration into industrial networks while maintaining a compact physical profile suitable for space-constrained control panels.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonochrome STN Display:\u003c\/strong\u003e 5.7-inch LCD with a resolution of 320 x 240 pixels (QVGA), offering clear visual feedback for plant floor status.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpanded Communications:\u003c\/strong\u003e Equipped with an RJ-45 Ethernet port supporting FINS\/TCP and FINS\/UDP, alongside two standard RS-232C serial interfaces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUSB Slave Port:\u003c\/strong\u003e Dedicated Type B USB connector enabling high-speed transfer of system configurations and screen layouts from CX-Designer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstantial System Memory:\u003c\/strong\u003e 60 MB of internal storage accommodates complex user projects, graphic libraries, and alarm log histories.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Front panel constructed to IP65f standards, shielding internal electronics against splashing water, oil mist, and non-corrosive dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling \u0026amp; Conveyors:\u003c\/strong\u003e Local display of routing directories, motor diagnostics, and operational speeds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater Treatment:\u003c\/strong\u003e Cost-effective visual status display for isolated pumping stations and valve sequences.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Local machine control interfaces requiring real-time alarm reporting and serial\/Ethernet PLC connectivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC Control Panels:\u003c\/strong\u003e Monitoring air quality parameters, setpoint adjustments, and fan speed diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px 12px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px 12px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eNS5-MQ11B-V2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eSTN Monochrome LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e5.7 inches (diagonal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e320 x 240 pixels (QVGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eTouch Panel Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eAnalog resistive matrix\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eOperating Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e20.4 to 27.6 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e15 Watts maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eEthernet Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e1x 10\/100Base-T (RJ-45)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eSerial Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e2x RS-232C (D-Sub 9-pin female)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e1x USB Type B (Slave, USB 1.1 equivalent)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eInternal Screen Data Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e60 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eBacklight Service Life\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e50,000 operating hours minimum (at 25 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eFront Panel Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eIP65f (Dust-tight, water-resistant, oil-resistant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eBezel \/ Case Color\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eBlack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e1.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e255 x 210 x 115 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe system's rear panel provides accessible, dedicated interfaces for connecting to industrial networks and auxiliary system storage.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px 12px; font-weight: bold;\"\u003ePort \/ Interface\u003c\/th\u003e\n        \u003cth style=\"padding: 8px 12px; font-weight: bold;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px 12px; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eSerial Port A\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eD-Sub 9-pin female\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eHost Link (RS-232C) communication to primary PLC or controller.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eSerial Port B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eD-Sub 9-pin female\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eAuxiliary Host Link or connection to temperature controllers and barcode readers.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eRJ-45 (10\/100 Mbps)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eNetwork communication to Sysmac PLCs, network drives, and remote computers.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eUSB Slave Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eUSB Type B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eHigh-speed screen data upload\/download using CX-Designer software.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eExpansion Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eCompactFlash Card Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eData logging, recipe management, and system firmware updates.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe -V2 designation indicates Version 2 hardware. If replacing an older, non-V2 NS5 terminal, you can convert older .IPP runtime files directly using CX-Designer. However, note that newer -V2 hardware features enhanced touch response algorithms and a larger native screen configuration memory (60 MB compared to the older 4 MB standard on early-generation units).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eSTN liquid crystal displays are sensitive to ambient operating temperatures. When operating the NS5-MQ11B-V2 in environments below 5 degC, display update times (screen switching and numeric shifts) will slow down naturally due to the physics of the liquid crystal layer. For critical fast-changing variables, ensure the display is enclosed in a temperature-regulated panel or allow pre-heating cycles.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent communication dropouts via the RS-232C serial ports, ensure that your serial cables do not exceed 15 meters in length. If using Serial Port A or B in electrically noisy environments alongside variable frequency drives (VFDs), install a functional ground wire directly from the terminal block on the back of the HMI to a low-resistance panel ground (less than 100 ohms). Shielded twisted-pair (STP) cabling must be used for the Ethernet connection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"margin: 0; color: #9b2c2c;\"\u003eDisconnect all electrical power sources before executing physical mounting or cable installation. Verify that the incoming supply line is rated strictly at 24 VDC. Supplying alternating current (AC) or voltages exceeding 27.6 VDC will cause immediate, irreversible damage to the HMI's internal power supply filter and logic components.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003ePrepare a clean, rectangular panel cutout of exactly 184 mm (width) by 131 mm (height) in a metal sheet with a thickness between 1.6 mm and 4.8 mm.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eEnsure the IP65 rubber sealing gasket is seated flatly and continuously along the front bezel groove without twists or overlaps.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInsert the NS5-MQ11B-V2 terminal through the front panel. Fasten the provided retaining mounting brackets into the chassis grooves from the rear, tightening screws to a precise torque of 0.5 to 0.6 N-m to maintain IP65 integrity.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the 24 VDC power supply cables to the terminal block using M3 ring lugs. Ensure correct polarity: Positive (+) to 24V terminal, Negative (-) to 0V terminal, and connect the Functional Ground (FG) directly to the cabinet ground bus.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077911142763,"sku":"NS5-MQ11B-V2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ns5-mq11b-v2-tgia2jf2zll.png?v=1775733912","url":"https:\/\/www.plcprotech.com\/products\/omron-ns5-mq11b-v2-ns-series-programmable-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}