{"product_id":"omron-nx102-1020-sysmac-nx1-modular-cpu","title":"Omron NX102-1020 Sysmac NX1 Modular CPU","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for real-time machine control and industrial information integration, the \u003cstrong\u003eNX102-1020\u003c\/strong\u003e serves as a high-performance \u003cstrong\u003emodular CPU\u003c\/strong\u003e within the Omron Sysmac platform. This controller seamlessly bridges the gap between operational technology (OT) and information technology (IT) by offering built-in database connection capabilities alongside synchronized motion and sequence control. The integration of OPC-UA and SQL client functionality enables direct data exchange between production machinery and enterprise-level IT databases without requiring intermediate gateways or PC hardware.\u003c\/p\u003e\n\n\u003cp\u003eOperating with a fast primary task cycle time of 1 ms, this unit coordinates high-speed sequence processing and complex motion pathways. Communication flexibility is maintained through integrated EtherCAT, EtherNet\/IP, and standard TCP\/IP Ethernet interfaces, ensuring high compatibility with decentralized modern plant architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect SQL database connection functionality for secure and efficient IT-OT data mapping.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in OPC-UA server capabilities to facilitate standardized, secure industrial communication.\u003c\/li\u003e\n  \u003cli\u003eSynchronized motion control supporting up to 2 synchronous axes and 4 point-to-point (PTP) axes.\u003c\/li\u003e\n  \u003cli\u003eGenerous onboard memory with 5 MB allocated for program storage and 33.5 MB for variables.\u003c\/li\u003e\n  \u003cli\u003eExpansive local and remote expansion support, handling up to 32 local NX I\/O units and up to 64 remote I\/O nodes via the NX I\/O Bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTraceability and Quality Control: Direct database logging for pharmaceutical, food processing, and automotive assembly lines.\u003c\/li\u003e\n  \u003cli\u003eHigh-Speed Packaging Machinery: Synchronous motion control for cartoners, flow-wrappers, and labeling systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial Handling Systems: Direct PLC-to-database communication for automated storage and retrieval systems (ASRS) and high-speed sorting lanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX102-1020\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSysmac NX1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController Functionality\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDatabase connection, Motion control, OPC-UA, Position control, Sequence control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Synchronous Axes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of PTP Axes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Axes (incl. virtual)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Task Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVariables Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e33.5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Port(s)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Option(s)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSerial RS-232C, Serial RS-422, Serial RS-485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Remote I\/O Nodes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Expansion Units\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 cm x 6.6 cm x 10 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePort\/Interface\u003c\/th\u003e\n      \u003cth\u003eFunction and Protocols\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port\u003c\/td\u003e\n      \u003ctd\u003eMaster interface for high-speed local and remote motion and I\/O networking\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherNet\/IP Ports\u003c\/td\u003e\n      \u003ctd\u003eDual ports for plant-level industrial ethernet communication, database connection, and OPC-UA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Port\u003c\/td\u003e\n      \u003ctd\u003ePeripheral tool port for configuration, programming, and monitoring via Sysmac Studio\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNX Bus Interface\u003c\/td\u003e\n      \u003ctd\u003eDirect right-side connection backplane for local NX I\/O units\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMounting Method: Securely mount the CPU unit to a standard 35 mm DIN rail inside an industrial enclosure.\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Clearance: Ensure sufficient clearance above and below the module to facilitate natural convection cooling.\u003c\/li\u003e\n  \u003cli\u003eWiring and Grounding: Maintain a low-impedance connection to the functional ground terminal to shield the system from electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eExpansion Limits: Ensure the total power consumption of the attached local NX I\/O modules does not exceed the power supply capacity of the NX102-1020.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077898920299,"sku":"NX102-1020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx102-1020-l3ymft0eo5f.png?v=1775734033","url":"https:\/\/www.plcprotech.com\/products\/omron-nx102-1020-sysmac-nx1-modular-cpu","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}