{"product_id":"omron-nx102-1100-sysmac-nx1-modular-cpu","title":"Omron NX102-1100 Sysmac NX1 Modular CPU","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for high-speed machine control and seamless IT\/OT integration, the \u003cstrong\u003eOmron NX102-1100\u003c\/strong\u003e controller brings synchronized motion, sequence control, and native OPC-UA industrial connectivity to the \u003cstrong\u003eSysmac NX1\u003c\/strong\u003e platform. This modular CPU simplifies automation architectures by executing logic and motion control within a single task cycle, enabling high-precision operations in complex manufacturing environments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Motion Control:\u003c\/strong\u003e Supports up to 4 synchronized axes and 4 PTP axes, handling up to 15 total axes including virtual axes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Connectivity:\u003c\/strong\u003e Built-in EtherCAT master, EtherNet\/IP, Ethernet TCP\/IP, and USB ports for comprehensive factory networking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Execution:\u003c\/strong\u003e Primary task cycle time of 1 ms ensures real-time responsiveness for demanding applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpandable Architecture:\u003c\/strong\u003e Supports up to 32 expansion units on the local NX I\/O Bus and up to 64 remote I\/O nodes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Memory:\u003c\/strong\u003e Features 5 MB of program memory and 33.5 MB of variables memory to accommodate complex application code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-speed packaging and sorting machinery\u003c\/li\u003e\n  \u003cli\u003eMulti-axis pick-and-place robotic systems\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly and material handling systems\u003c\/li\u003e\n  \u003cli\u003eReal-time data collection and cloud connectivity via OPC-UA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0; font-size: 14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ SKU\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNX102-1100\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eController Functionality\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMotion control, OPC-UA, Position control, Sequence control\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Synchronous Axes\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. PTP Axes\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Total Axes (including virtual)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e15\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePrimary Task Cycle Time\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProgram Memory\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eVariables Memory\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e33.5 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBuilt-in Communication Ports\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOptional Communication Interfaces\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSerial RS-232C, Serial RS-422, Serial RS-485\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eI\/O System Compatibility\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNX I\/O Bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Expansion Units\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e32\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Remote I\/O Nodes\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e64\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDimensions (L x W x H)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10.0 cm x 6.6 cm x 10.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0; font-size: 14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEtherCAT Master Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSynchronous real-time control of up to 4 axes and remote I\/O terminal modules.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEtherNet\/IP Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDual-port Ethernet hub configuration supporting tag data links, message communications, and OPC-UA.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eType-B USB port for local configuration, maintenance, and connection with Sysmac Studio.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOption Board Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAccommodates Serial option boards (RS-232C, RS-422, or RS-485) for legacy hardware integration.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  This modular CPU serves as an ideal step-up from the NX1P2 series when higher axis-synchronization counts and native OPC-UA server functionality are required. Ensure your project is programmed via Sysmac Studio version 1.22 or higher; older software revisions will not support this CPU's hardware-defined features.\n\u003c\/p\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When designing the network topology, note that the EtherNet\/IP and EtherCAT networks run on independent physical layers. Avoid bridging these networks through unmanaged switches, as it can degrade the 1 ms deterministic performance of the EtherCAT master loop.\n\u003c\/p\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To prevent electrical noise propagation, ensure the functional ground terminal on the NX102-1100 unit is connected directly to a dedicated copper ground plate. When adding NX-series expansion modules, double-check that the total current draw does not exceed the maximum internal bus power output; install additional power supply modules (NX-PF) where required.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 0 4px 4px 0;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: SAFETY FIRST\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 14px;\"\u003e\n    Always de-energize the entire control panel prior to mounting or dismounting the CPU unit and adjacent expansion modules. Do not touch terminal blocks while the power is ON to avoid electric shock or system malfunction.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 8px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the CPU unit securely onto a standard 35mm DIN rail using the integrated locking mechanism.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 8px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign and connect the Sysmac NX I\/O expansion modules to the right-hand side of the CPU, ensuring the slide locks engage fully.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 8px; font-weight: bold; font-size: 14px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect industrial Ethernet cables to the dedicated EtherCAT and EtherNet\/IP ports, keeping signal lines separate from high-voltage power lines.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077920186731,"sku":"NX102-1100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx102-1100-fpxhs0svp4z.png?v=1775734034","url":"https:\/\/www.plcprotech.com\/products\/omron-nx102-1100-sysmac-nx1-modular-cpu","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}