{"product_id":"omron-nxeic202-omron-nx-series-ethernet-ip-coupler-unit","title":"Omron NXEIC202 | Omron | NX-Series EtherNet\/IP Coupler Unit","description":"\u003cp\u003eThe \u003cstrong\u003eNXEIC202\u003c\/strong\u003e is an \u003cstrong\u003eEtherNet\/IP Coupler Unit\u003c\/strong\u003e from the \u003cstrong\u003eOmron NX-Series\u003c\/strong\u003e, serving as the gateway between the EtherNet\/IP network and the modular \u003cstrong\u003eNX I\/O Bus\u003c\/strong\u003e system. This unit acts as a bridge, allowing controllers to communicate with and control multiple I\/O modules seamlessly over an EtherNet\/IP protocol. By utilizing two communication ports, it supports flexible network topologies, making it suitable for distributed control architectures in high-performance industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Connectivity:\u003c\/strong\u003e Features dual communication ports for efficient data exchange and network integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular I\/O System:\u003c\/strong\u003e Designed to interface directly with the \u003cstrong\u003eNX I\/O Bus\u003c\/strong\u003e, supporting a wide variety of digital, analog, and specialty I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Optimized dimensions of 100 mm x 46 mm x 80 mm for high-density control cabinet layouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Rated for use in controlled, dust-free industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed I\/O systems for automated manufacturing lines.\u003c\/li\u003e\n\u003cli\u003eRemote control and monitoring in PLC-based automation architectures.\u003c\/li\u003e\n\u003cli\u003eHigh-speed data acquisition across factory-floor networks.\u003c\/li\u003e\n\u003cli\u003eIntegration into modular machine control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNXEIC202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP Coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBus Coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e100 mm x 46 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIL (IEC 61508)\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e The unit is designed for standard DIN rail installation. Ensure it is securely locked onto the rail to maintain structural integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Proper grounding is essential to minimize noise and ensure stable communication. Connect the functional ground terminal to a low-impedance earth point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded twisted-pair Ethernet cables (Cat5e or higher) to prevent EMI\/RFI issues in industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain physical separation between Ethernet communication lines and high-power cables to prevent signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Ensure sufficient airflow around the module. Avoid mounting it directly above high-heat components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077936669035,"sku":"NXEIC202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nxeic202-nhtbvkqwghs.png?v=1775734055","url":"https:\/\/www.plcprotech.com\/products\/omron-nxeic202-omron-nx-series-ethernet-ip-coupler-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}