{"product_id":"pepperl-fuchs-214240-kcd2-sot-ex1-lb-switch-amplifier","title":"Pepperl+Fuchs 214240 KCD2-SOT-Ex1.LB Switch Amplifier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Pepperl+Fuchs \u003cstrong\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e is a 1-channel isolated barrier designed for intrinsic safety applications to transfer digital signals from hazardous areas to safe areas. This device features a single field-side digital input that controls two passive transistor outputs on the control side. Configurable via DIP switches, the unit can function as a signal splitter (1 input and 2 outputs) or assign its second transistor output as an error indicator. The \u003cstrong\u003eKCD2-SOT-Ex1.LB\u003c\/strong\u003e switch amplifier supports line fault detection (LFD) for monitoring lead breakage and short circuits, and processes signals from dry contacts or NAMUR sensors according to EN 60947-5-6.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel isolated barrier for intrinsic safety applications\u003c\/li\u003e\n\u003cli\u003e24 V DC supply via removable screw terminals or Power Rail\u003c\/li\u003e\n\u003cli\u003eDry contact or NAMUR sensor input\u003c\/li\u003e\n\u003cli\u003e2 passive transistor outputs with reversible mode of operation\u003c\/li\u003e\n\u003cli\u003eUsable as a signal splitter (1 input to 2 outputs)\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD) for lead breakage and short-circuit monitoring\u003c\/li\u003e\n\u003cli\u003eCollective error message output via Power Rail\u003c\/li\u003e\n\u003cli\u003eFront-accessible DIP switches for operational mode and fault detection configuration\u003c\/li\u003e\n\u003cli\u003eCompact 12.5 mm housing width for DIN mounting rail installation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) safety evaluation according to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsic safety signal isolation and processing in hazardous areas\u003c\/li\u003e\n\u003cli\u003eSignal splitting from a single field sensor to multiple control devices\u003c\/li\u003e\n\u003cli\u003eInterface conversion for NAMUR proximity sensors and discrete dry contact switches\u003c\/li\u003e\n\u003cli\u003eStatus monitoring and line fault detection in DCS, SIS, and PLC automation loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKCD2-SOT-Ex1.LB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e214240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Integrity Level (SIL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2 (Systematic Capability SC 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Ur)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 ... 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ... 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 700 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Side Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminals 1+, 2- (NAMUR acc. to EN 60947-5-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Voltage \/ Short-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 10 V DC \/ approx. 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Point \/ Hysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 ... 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreakage I \u0026lt;= 0.1 mA, Short-circuit I \u0026gt;= 6.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse \/ Pause Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emin. 100 us \/ min. 100 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Side Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput I: terminals 5+, 6-; Output II: terminals 7+, 8-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive Transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rated Voltage (Ur)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 200 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-signal: (external voltage) - 3 V max. for 50 mA; 0-signal: off-state current \u0026lt;= 10 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation (Input\/Output, Input\/Power)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReinforced insulation acc. to EN 50178, rated voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation (Output\/Power, Output\/Output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic insulation acc. to EN 50178, rated voltage 50 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafe Electrical Isolation (Hazardous to Safe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 ... 60 degC (-4 ... 140 degF), extended up to 70 degC (158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn 35 mm DIN mounting rail acc. to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch), housing type A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField Input + (Hazardous Area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField Input - (Hazardous Area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput I Transistor +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput I Transistor -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput II Transistor +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput II Transistor -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage 24 V DC +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage 24 V DC -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rail\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage 24 V DC \/ Collective Error Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the module onto a 35 mm DIN mounting rail complying with EN 60715:2001.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Connect hazardous area field wiring to the top blue removable terminal block (terminals 1+, 2-). Connect safe area output and power wiring to the bottom green removable terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Supply 19 ... 30 V DC via screw terminals 9+ and 10- or directly through the Power Rail system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Set front DIP switches (S1, S2, S3) to select output active mode, assign output II function, and enable or disable line fault detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Precautions:\u003c\/strong\u003e Ensure intrinsic safety parameters (Uo = 10.5 V, Io = 17.1 mA, Po = 45 mW) match field device specifications and maximum safe voltage (Um = 253 V AC) limits are respected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integrity Level:\u003c\/strong\u003e SIL 2, Systematic Capability SC 3 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Certification:\u003c\/strong\u003e BASEEFA 13 ATEX 0080, CML 19 ATEX 4410 X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Marking:\u003c\/strong\u003e II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I, II 3G Ex ec IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx Certification:\u003c\/strong\u003e IECEx BAS 13.0046, IECEx CML 19.0147X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx Marking:\u003c\/strong\u003e [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I, Ex ec IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Control drawing 116-0374 (cULus)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Directive 2014\/30\/EU, EN 61326-1:2013, NE 21:2011\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Standards:\u003c\/strong\u003e IEC 60529:2001 (IP20), IEC 61010-1:2010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Standard:\u003c\/strong\u003e EN 60947-5-6:2000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl + Fuchs","offers":[{"title":"Default Title","offer_id":53710572323179,"sku":"KCD2-SOT-Ex1.LB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Pepperl-Fuchs-214240-KCD2-SOT-Ex1-LB_001_1200x1200_f09c0194-1a44-46b6-9a88-6a2962a66113.jpg?v=1786506086","url":"https:\/\/www.plcprotech.com\/products\/pepperl-fuchs-214240-kcd2-sot-ex1-lb-switch-amplifier","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}