{"product_id":"rosemount-8800df120sa1n7d1e1i1m5c4cn7q4q8-8800d-vortex-flowmeter","title":"Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 8800D Vortex Flowmeter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for highly reliable steam, liquid, and gas flow measurement, the \u003cstrong\u003eRosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8\u003c\/strong\u003e is an industrial inline vortex flowmeter utilizing a non-clogging sensor design to eliminate impulse lines and potential leak points. This specific configuration features a massive 12-inch (300 mm) flanged body constructed of robust CF-3M cast stainless steel and 316 wrought stainless steel wetted materials, capable of handling demanding industrial process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe system is equipped with 4-20 mA digital electronics running the HART communication protocol, enabling seamless diagnostic monitoring and configuration. To ensure operator clarity on-site, a high-visibility M5 LCD display is built directly into the rugged stainless steel transmitter housing, which is configured with two M20 x 1.5 conduit entries. For safety compliance, this model comes certified with ATEX dual protection—both Flameproof (E1) and Intrinsic Safety (I1)—and includes comprehensive Q4 calibration and Q8 material traceability documentation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAll-Welded Design:\u003c\/strong\u003e Eliminates internal gaskets, ports, and bypass lines, preventing process bypass and potential leak paths.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdaptive Digital Signal Processing:\u003c\/strong\u003e Provides reliable flow signal tracking while filtering out ambient process vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX Dual Certification:\u003c\/strong\u003e Flameproof and Intrinsic Safety approvals for deployment in classified hazardous industrial zones.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Operator Interface:\u003c\/strong\u003e Includes an integrated M5 LCD indicator showing process variables and diagnostics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable Alarms:\u003c\/strong\u003e Dual NAMUR C4 (high alarm) and CN (low alarm) saturation and alarm values protect process equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuality Documentation:\u003c\/strong\u003e Ships with ISO 10474 3.1\/EN 10204 3.1 calibration and material traceability certificates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-capacity steam utility lines and boiler feedwater monitoring.\u003c\/li\u003e\n  \u003cli\u003eIndustrial gas distribution and compressed air management.\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical process fluid allocation.\u003c\/li\u003e\n  \u003cli\u003ePower plant cooling water and condensate loop measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eRosemount (Emerson)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003e8800DF120SA1N7D1E1I1M5C4CN7Q4Q8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMeter Style\u003c\/strong\u003e\n      \u003ctd\u003eF - Standard flanged body style\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLine Size\u003c\/strong\u003e\n      \u003ctd\u003e12 inch (300 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWetted Materials\u003c\/strong\u003e\n      \u003ctd\u003eCF-3M Cast Stainless Steel \/ 316 Wrought Stainless Steel (316\/316L)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eFlange Class and Connection\u003c\/strong\u003e\n      \u003ctd\u003eASME B16.5 RF Class 150\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProcess Temperature Range\u003c\/strong\u003e\n      \u003ctd\u003e-40 to +450 degF (-40 to +232 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHousing Material\u003c\/strong\u003e\n      \u003ctd\u003eStainless steel housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConduit Entries\u003c\/strong\u003e\n      \u003ctd\u003eTwo M20 x 1.5 conduit entries\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOutputs\u003c\/strong\u003e\n      \u003ctd\u003e4-20 mA digital electronics (HART Protocol)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCalibration Type\u003c\/strong\u003e\n      \u003ctd\u003eFlow calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\n      \u003ctd\u003eATEX Flameproof (E1) \u0026amp; ATEX Intrinsic Safety ia\/ic (I1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDisplay\u003c\/strong\u003e\n      \u003ctd\u003eM5 LCD indicator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAlarm Configuration\u003c\/strong\u003e\n      \u003ctd\u003eC4 NAMUR high alarm, CN NAMUR low alarm and saturation values\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eQuality Certificates\u003c\/strong\u003e\n      \u003ctd\u003eISO 10474 3.1\/EN 10204 3.1 Calibration (Q4) \u0026amp; Material Traceability (Q8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDevice Weight\u003c\/strong\u003e\n      \u003ctd\u003e298 lb (135 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eShipping Weight\u003c\/strong\u003e\n      \u003ctd\u003e136 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal \/ Port\u003c\/th\u003e\n      \u003cth\u003eFunctional Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePWR\/COMM +\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePositive loop power supply input and HART digital communications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePWR\/COMM -\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNegative loop power supply input and common return\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTEST + \/ -\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLoop current verification terminal (allows measurement without breaking loop)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Ground\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eElectronic housing safety ground termination point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExternal Ground\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExternal chassis equipotential grounding lug\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStraight Pipe Runs:\u003c\/strong\u003e To ensure accurate flow measurement, install the meter with a minimum of 10 nominal pipe diameters upstream and 5 nominal pipe diameters downstream of straight pipe, free from valves or fittings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Can be installed in horizontal, vertical, or inclined piping. Vertical mounting with upward process flow is recommended to keep the sensor completely flooded.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Sealing:\u003c\/strong\u003e Install appropriate certified cable glands or conduit seals in the M20 x 1.5 entries to maintain the NEMA 4X \/ IP66\/67 environmental rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always ground the transmitter housing to earth using the internal or external grounding screw terminals in accordance with local hazardous area codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX Directive compliance for hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003eFlameproof certification: ATEX II 2 G Ex d IIB+H2 T6 Gb (E1 option).\u003c\/li\u003e\n  \u003cli\u003eIntrinsic Safety certification: ATEX II 1 G Ex ia IIC T4 Ga (I1 option).\u003c\/li\u003e\n  \u003cli\u003eISO 10474 \/ EN 10204 Type 3.1 material and calibration verification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Rosemount","offers":[{"title":"Default Title","offer_id":52679230914923,"sku":"8800DF120SA1N7D1E1I1M5C4CN7Q4Q8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8800df120sa1n7d1e1i1m5c4cn7q4q8-del2yd52gsu_8120ab8a-daa3-49cc-9836-23d9e6ac170a.jpg?v=1765958111","url":"https:\/\/www.plcprotech.com\/products\/rosemount-8800df120sa1n7d1e1i1m5c4cn7q4q8-8800d-vortex-flowmeter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}