{"product_id":"schneider-altistart-1-ats01n212lu-soft-starters","title":"Schneider Altistart 1 ATS01N212LU Soft Starters","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS01N212LU\u003c\/strong\u003e is an \u003cstrong\u003eAltistart 01 soft starter\u003c\/strong\u003e engineered to provide smooth starting for asynchronous motors in various industrial applications. Designed for a current rating of \u003cstrong\u003e12 A\u003c\/strong\u003e, this unit operates within a supply voltage range of \u003cstrong\u003e200-240V\u003c\/strong\u003e and is suitable for motor power ratings between \u003cstrong\u003e2.2 kW and 3 kW\u003c\/strong\u003e. By controlling the torque and voltage supplied to the motor, the \u003cstrong\u003eATS01N212LU\u003c\/strong\u003e reduces mechanical stress during start-up, helping to extend the lifespan of mechanical components and minimize current surges on the electrical network.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for \u003cstrong\u003e12 A\u003c\/strong\u003e asynchronous motor control.\u003c\/li\u003e\n\u003cli\u003eSupports motor power ratings from \u003cstrong\u003e2.2 kW to 3 kW\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWide voltage input range of \u003cstrong\u003e200-240V\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCompact design for space-constrained industrial panels.\u003c\/li\u003e\n\u003cli\u003eProvides smooth acceleration and deceleration to reduce mechanical wear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConveyor systems and material handling equipment.\u003c\/li\u003e\n\u003cli\u003eSmall fan and blower control.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and hydraulic pumps.\u003c\/li\u003e\n\u003cli\u003eMachines requiring controlled torque ramp-up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e2.2-3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.5 x 15.2 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The device should be installed vertically on a DIN rail or panel to ensure proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain sufficient space around the unit to allow for natural airflow, as efficient cooling is required during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the power supply and motor cables according to the provided wiring diagram, ensuring all terminals are tightened to the specified torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e It is recommended to install appropriate circuit protection (fuses or circuit breakers) upstream to protect the soft starter and motor from short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation environment is free from excessive dust, moisture, and corrosive gases to maintain long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104571154795,"sku":"ATS01N212LU","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats01n212lu-4qsu0kshvvv.png?v=1776162041","url":"https:\/\/www.plcprotech.com\/products\/schneider-altistart-1-ats01n212lu-soft-starters","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}