{"product_id":"schneider-altistart-22-ats22c32s6u-soft-starter","title":"Schneider Altistart 22 ATS22C32S6U Soft Starter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS22C32S6U\u003c\/strong\u003e is an \u003cstrong\u003eAltistart 22 soft starter\u003c\/strong\u003e engineered for the control of three-phase asynchronous motors. This unit is rated for 320 A and operates within a voltage range of 208 V to 600 V, providing support for motor power applications from 100 HP to 300 HP. It utilizes advanced torque control to provide smooth acceleration and deceleration, effectively reducing mechanical stress on the drive train and minimizing voltage dips during the motor startup phase.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated operational current: 320 A\u003c\/li\u003e\n\u003cli\u003eSupports supply voltages from 208 V to 600 V\u003c\/li\u003e\n\u003cli\u003eMotor power capacity: 100 HP to 300 HP\u003c\/li\u003e\n\u003cli\u003eIntegrated bypass contactor to optimize thermal efficiency\u003c\/li\u003e\n\u003cli\u003eAdvanced diagnostic capabilities for simplified maintenance\u003c\/li\u003e\n\u003cli\u003eCompact design suitable for integration into industrial control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty centrifugal pumps\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation and fan systems\u003c\/li\u003e\n\u003cli\u003eLarge-scale compressor units\u003c\/li\u003e\n\u003cli\u003eBelt-driven conveyor systems\u003c\/li\u003e\n\u003cli\u003eHigh-inertia mechanical loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e208-600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating\u003c\/td\u003e\n\u003ctd\u003e100 - 300 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e60 x 40 x 46 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e24.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the unit is installed vertically on a solid, fire-resistant surface to allow for proper air convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain recommended clearance distances around the unit to prevent thermal overload and ensure peak performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize heavy-duty power cabling rated for 320 A. Verify that all power and control connections are tightened to the torque specifications provided in the user manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e A robust protective earth (PE) connection must be maintained to ensure safe operation and mitigate electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Coordinate the installation with appropriate upstream short-circuit protection devices and thermal monitoring to comply with industrial safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573907307,"sku":"ATS22C32S6U","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats22c32s6u-gc5abhimcyw.png?v=1776162062","url":"https:\/\/www.plcprotech.com\/products\/schneider-altistart-22-ats22c32s6u-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}