{"product_id":"schneider-altistart-48-ats48d88y-soft-starter","title":"Schneider Altistart 48 ATS48D88Y Soft Starter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS48D88Y\u003c\/strong\u003e is a high-performance \u003cstrong\u003esoft starter\u003c\/strong\u003e from the \u003cstrong\u003eAltistart 48\u003c\/strong\u003e range, engineered to provide smooth acceleration and deceleration for asynchronous motors. Rated for a nominal current of \u003cstrong\u003e77 A\u003c\/strong\u003e, this unit supports a wide power range from \u003cstrong\u003e18.5 kW to 75 kW\u003c\/strong\u003e and operates across a supply voltage spectrum of \u003cstrong\u003e208–690 V\u003c\/strong\u003e. It utilizes advanced torque control technology to reduce mechanical stress on connected machinery, making it an essential solution for applications such as pumps, fans, and compressors where minimizing starting torque surges is critical.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e77 A nominal current rating\u003c\/li\u003e\n\u003cli\u003eWide voltage support: 208–690 V\u003c\/li\u003e\n\u003cli\u003ePower range: 18.5 kW to 75 kW\u003c\/li\u003e\n\u003cli\u003eAdvanced torque control for smooth motor start\/stop\u003c\/li\u003e\n\u003cli\u003eIntegrated thermal motor protection\u003c\/li\u003e\n\u003cli\u003eDesigned for standard asynchronous motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial pump systems\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial fan controls\u003c\/li\u003e\n\u003cli\u003eCompressor motor soft-starting\u003c\/li\u003e\n\u003cli\u003eConveyor belt start-up management\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose machine tool motor control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart 48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Current\u003c\/td\u003e\n\u003ctd\u003e77 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e208–690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Range\u003c\/td\u003e\n\u003ctd\u003e18.5–75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (cm)\u003c\/td\u003e\n\u003ctd\u003e40.00 x 36.50 x 30.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the soft starter is installed vertically to maximize natural cooling airflow. Maintain specified minimum clearances around the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Install in a location free from excessive dust, corrosive gases, and humidity. Ensure the ambient temperature is within the manufacturer's specified operational range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate cable cross-sections for the 77 A rated current. Ensure secure connections to the power terminals and properly grounded bypass contactors if external bypass is used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Configure the integrated thermal protection settings according to the specific motor nameplate data to prevent motor burnout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Allow adequate time for internal components to discharge before performing maintenance or inspection on the terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104569319787,"sku":"ATS48D88Y","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats48d88y-0ojsjvywlxa.png?v=1776162126","url":"https:\/\/www.plcprotech.com\/products\/schneider-altistart-48-ats48d88y-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}