{"product_id":"schneider-altivar-212-atv212wd15n4c-variable-frequency-drives","title":"Schneider Altivar 212 ATV212WD15N4C Variable Frequency Drives","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATV212WD15N4C\u003c\/strong\u003e is a \u003cstrong\u003efrequency controller\u003c\/strong\u003e from the \u003cstrong\u003eAltivar 212\u003c\/strong\u003e range, specifically designed to provide high-efficiency speed control for three-phase asynchronous motors. Rated for \u003cstrong\u003e15 kW\u003c\/strong\u003e operation at \u003cstrong\u003e480V\u003c\/strong\u003e, this \u003cstrong\u003evariable frequency drive\u003c\/strong\u003e is optimized for building automation, pump, and fan applications. The unit features an \u003cstrong\u003eEMC class C1\u003c\/strong\u003e filter to ensure compliance with stringent electromagnetic compatibility requirements in sensitive environments and is enclosed in an \u003cstrong\u003eIP55\u003c\/strong\u003e-rated housing, providing protection against dust and water jets. The \u003cstrong\u003eATV212WD15N4C\u003c\/strong\u003e delivers reliable performance for complex HVAC and fluid management systems, ensuring energy efficiency and precise motor operation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for \u003cstrong\u003e15 kW\u003c\/strong\u003e motor power applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-phase (3F)\u003c\/strong\u003e power input compatibility.\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eEMC class C1\u003c\/strong\u003e filter for reduced signal interference.\u003c\/li\u003e\n\u003cli\u003eRobust \u003cstrong\u003eIP55\u003c\/strong\u003e enclosure for installation in demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003eDedicated \u003cstrong\u003eAltivar 212\u003c\/strong\u003e architecture for enhanced control of HVAC and pumping systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial and industrial HVAC fan control.\u003c\/li\u003e\n\u003cli\u003ePump systems for water treatment and distribution.\u003c\/li\u003e\n\u003cli\u003eAutomated building control systems.\u003c\/li\u003e\n\u003cli\u003eAir handling units and blowers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltivar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable frequency drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filter\u003c\/td\u003e\n\u003ctd\u003eClass C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e80 x 40 x 39 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e31.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Utilize the \u003cstrong\u003eIP55\u003c\/strong\u003e enclosure to mount the drive in positions where it may be exposed to dust or splashing water. Ensure the surface can support the 31.50 kg weight of the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Although the unit has a high ingress protection rating, ensure that external heat dissipation is accounted for if the drive is installed in a confined space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e A robust connection to the building earth system is mandatory to ensure the effectiveness of the \u003cstrong\u003eEMC class C1\u003c\/strong\u003e filter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route power and signal cables separately to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the ambient temperature is within the manufacturer's specified range for \u003cstrong\u003eAltivar 212\u003c\/strong\u003e drives to prevent derating and extend the service life of internal components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104571089259,"sku":"ATV212WD15N4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv212wd15n4c-o1bjqrv1ybn.png?v=1776162204","url":"https:\/\/www.plcprotech.com\/products\/schneider-altivar-212-atv212wd15n4c-variable-frequency-drives","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}