{"product_id":"schneider-altivar-212-atv212wd45n4c-variable-frequency-drive","title":"Schneider Altivar 212 ATV212WD45N4C Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATV212WD45N4C\u003c\/strong\u003e is a high-performance \u003cstrong\u003evariable frequency drive\u003c\/strong\u003e from the \u003cstrong\u003eAltivar 212\u003c\/strong\u003e series, specifically engineered for HVAC (Heating, Ventilation, and Air Conditioning) applications. With a power rating of \u003cstrong\u003e45 kW\u003c\/strong\u003e and an input voltage of \u003cstrong\u003e480V (3-phase)\u003c\/strong\u003e, this \u003cstrong\u003efrequency controller\u003c\/strong\u003e is optimized for building management systems, pump control, and fan operation. The unit features an \u003cstrong\u003eIP55\u003c\/strong\u003e ingress protection rating, providing robust defense against dust and low-pressure water jets, and includes an integrated \u003cstrong\u003eEMC class C1 filter\u003c\/strong\u003e to ensure electromagnetic compatibility in commercial and industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Rating: 45 kW\u003c\/li\u003e\n\u003cli\u003eInput Voltage: 480V, 3-Phase\u003c\/li\u003e\n\u003cli\u003eIngress Protection: IP55 (suitable for wall-mounted or harsh environment installations)\u003c\/li\u003e\n\u003cli\u003eIntegrated EMC Filter: Class C1 compliance\u003c\/li\u003e\n\u003cli\u003eApplication Focus: HVAC, pumps, and fans\u003c\/li\u003e\n\u003cli\u003eOptimized energy efficiency for motor control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC system optimization\u003c\/li\u003e\n\u003cli\u003eCommercial building ventilation systems\u003c\/li\u003e\n\u003cli\u003eWater distribution and booster pump stations\u003c\/li\u003e\n\u003cli\u003eBuilding management system (BMS) integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltivar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATV212WD45N4C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e480 V (3-Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e77.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e116.00 cm x 44.00 cm x 45.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Due to the weight of 77 kg, ensure the mounting surface is structurally capable of supporting the drive. Use appropriate lifting equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain specified clearance distances around the unit to ensure adequate heat dissipation and airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Solidly ground the drive chassis to the main ground bus to ensure the effectiveness of the EMC filter and personnel safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Segregate power cabling from control and signal wiring to minimize inductive interference and ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Ensure the operating environment temperature is within the manufacturer's specified limits for IP55-rated enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104571646315,"sku":"ATV212WD45N4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv212wd45n4c-3iwahphjxy0.png?v=1776162209","url":"https:\/\/www.plcprotech.com\/products\/schneider-altivar-212-atv212wd45n4c-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}