{"product_id":"schneider-altivar-61-atv61hd15n4z-variable-frequency-drive","title":"Schneider Altivar 61 ATV61HD15N4Z Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATV61HD15N4Z\u003c\/strong\u003e is an \u003cstrong\u003eAltivar 61 variable frequency drive\u003c\/strong\u003e engineered for high-performance motor control in industrial HVAC and fluid management applications. This drive provides a power output of 15 kW (20 HP) and operates on a three-phase 480 V supply. The unit is housed in an IP20-rated enclosure and includes EMC filtering to mitigate electromagnetic interference. Note that this specific configuration is supplied without a graphic terminal. The \u003cstrong\u003eATV61HD15N4Z\u003c\/strong\u003e offers advanced control algorithms to ensure precise speed regulation, energy efficiency, and operational stability for various industrial motor systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower rating: 15 kW (20 HP)\u003c\/li\u003e\n\u003cli\u003eInput voltage: 480 V (Three-phase)\u003c\/li\u003e\n\u003cli\u003eIntegrated EMC filtering\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating\u003c\/li\u003e\n\u003cli\u003eCompact physical design for efficient panel integration\u003c\/li\u003e\n\u003cli\u003eConfiguration: Supplied without graphic terminal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC systems\u003c\/li\u003e\n\u003cli\u003eFluid management and pump control\u003c\/li\u003e\n\u003cli\u003eFan and ventilation systems\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial motor drive applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltivar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable frequency drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e15 kW (20 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e480 V (Three-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the drive in a vertical position on a stable, non-combustible surface. Ensure that the cooling airflow is not obstructed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Protect the unit from excessive dust, moisture, and corrosive vapors. Maintain ambient operating temperatures within the specified limits to prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain clear segregation between control wiring and power conductors to reduce electromagnetic interference. Use shielded motor cables for compliance with EMC requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the drive chassis to a solid protective earth (PE) terminal to ensure operator safety and reliable system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Note:\u003c\/strong\u003e As this unit is supplied without a graphic terminal, ensure an appropriate interface is available or already installed within the system for configuration and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573677931,"sku":"ATV61HD15N4Z","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv61hd15n4z-wqg2151selw.png?v=1776162557","url":"https:\/\/www.plcprotech.com\/products\/schneider-altivar-61-atv61hd15n4z-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}