{"product_id":"schneider-atv61hd22n4z-variable-speed-drive","title":"Schneider ATV61HD22N4Z Variable Speed Drive","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric ATV61HD22N4Z\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance variable frequency drive (VFD) from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAltivar 61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This series was specifically engineered for variable torque applications, making it a legacy standard for controlling pumps and fans in building management and industrial processes.\u003c\/p\u003e\n\u003cp\u003eThe \"Z\" suffix typically denotes a version supplied without the DC choke, often used in specific cabinet-build configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar 61 (ATV61)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 kW \/ 30 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 to 480 V AC (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 A (at 4 kHz \/ 400 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Transient Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e52.8 A (for 60 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Open Style)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eControl \u0026amp; Communication\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Laws:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScalar (\u003cspan class=\"math-inline\"\u003e$V\/f$\u003c\/span\u003e), Flux Vector Control (Sensorless), and specialized Energy Saving ratios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus and CANopen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports communication cards (Profibus, DeviceNet, Ethernet) and I\/O extension cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Application Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a specific law to reduce motor losses by up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30%\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunder low-load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePump\/Fan Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures integrated \"Catch on the Fly\" (restarting a spinning fan), sleep\/wake modes, and multi-pump control (with card).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafe Torque Off (PWR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal to prevent accidental motor starts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMacros for specialized functions like \"Pumping,\" \"Ventilation,\" or \"General Use\" simplify the initial setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for vertical mounting in an electrical enclosure. Because it is an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit, it must be protected from dust and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit generates approximately\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e685 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof heat at full load. Ensure the cabinet fan capacity is sufficient to keep the ambient temperature below\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$50^\\circ C$\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Choke:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNote that the \"Z\" version may require an external line reactor or DC choke to comply with harmonic distortion limits, depending on your local grid requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded motor cables to minimize electromagnetic interference (EMI). Keep control wiring and power wiring in separate conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this drive for a conveyor or crane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile possible, it is not recommended. The ATV61 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVariable Torque\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(pumps\/fans). For constant torque applications like conveyors or hoists, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAltivar 71 (ATV71)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor the newer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATV930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries is more appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the replacement model for the ATV61?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Altivar 61 series is now largely superseded by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAltivar Process ATV630\u003c\/strong\u003e. The ATV630 offers superior energy monitoring and embedded Ethernet as standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I clear a \"PLF\" (Phase Loss) fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the input power supply for a dropped phase. If the input is fine, inspect the DC bus connections. If you are running the motor on a test bench without a load, you may need to disable the \"Output Phase Loss\" check in the fault management menu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support PID control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ATV61 has a built-in PID regulator for pressure or flow control, allowing it to adjust motor speed based on a feedback signal from a 4-20mA or 0-10V sensor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403725163,"sku":"ATV61HD22N4Z","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-atv61hd22n4z-variable-speed-drive-ttezyqhr2on_0cb7a1e8-801a-4e60-84af-ea9464b643ec.jpg?v=1766133928","url":"https:\/\/www.plcprotech.com\/products\/schneider-atv61hd22n4z-variable-speed-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}