{"product_id":"schneider-electric-140amm09000-modicon-quantum-analog-input-output-module","title":"Schneider Electric 140AMM09000 Modicon Quantum Analog Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003einput\/output analog module\u003c\/strong\u003e is designed for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e to provide high-precision analog signal interfacing within industrial control systems. The hardware integrates a single-pole low-pass filter providing a attenuation of -3 dB at 21 Hz (+\/- 20%) on the input circuit to manage electrical noise and ensure signal integrity.\u003c\/p\u003e\n\u003cp\u003eConfigured with \u003cstrong\u003e6 channels\u003c\/strong\u003e in total, the unit provides \u003cstrong\u003e4 analog inputs\u003c\/strong\u003e and \u003cstrong\u003e2 analog outputs\u003c\/strong\u003e. It features an addressing requirement of \u003cstrong\u003e5 input words\u003c\/strong\u003e and \u003cstrong\u003e2 output words\u003c\/strong\u003e. The input channels accommodate both bipolar and unipolar ranges, including \u003cstrong\u003ebipolar current (+\/- 20 mA)\u003c\/strong\u003e, \u003cstrong\u003ebipolar voltage (+\/- 10 V, +\/- 5 V)\u003c\/strong\u003e, \u003cstrong\u003eunipolar current (0...20 mA)\u003c\/strong\u003e, and configured offsets such as \u003cstrong\u003e4...20 mA\u003c\/strong\u003e and \u003cstrong\u003e1...5 V\u003c\/strong\u003e. The output circuits operate within a \u003cstrong\u003e4...20 mA\u003c\/strong\u003e range with an external loop voltage requirement. This combination allows reliable data acquisition and control tracking in continuous process fields.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Modularity\u003c\/strong\u003e: Features a 6-channel architecture providing 4 independent inputs and 2 dedicated outputs within a standard module format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Input Capabilities\u003c\/strong\u003e: Supports multiple signal configurations including unipolar current, unipolar offset current, bipolar current, unipolar voltage, and bipolar voltage profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Noise Suppression\u003c\/strong\u003e: Incorporates an integrated single-pole low-pass filter rated at -3 dB at 21 Hz (+\/- 20%) on the input circuit paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion\u003c\/strong\u003e: Delivers up to 16-bit resolution for voltage inputs, 15-bit for standard current inputs, and 12-bit resolution for the analog output loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Bus Isolation\u003c\/strong\u003e: Provides electrical isolation rated at 500 V AC or 750 V DC for 1 minute between independent channels, channels and bus, and between input\/output blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostic LEDs\u003c\/strong\u003e: Equipped with direct local signaling including a green bus active status indicator, a red external fault indicator, and 6 green\/red status markers for per-channel status and faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater and wastewater treatment monitoring\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n\u003cli\u003eBoiler control and steam management systems\u003c\/li\u003e\n\u003cli\u003eContinuous speed and position tracking loops\u003c\/li\u003e\n\u003cli\u003eMulti-channel data acquisition systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Input Number\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Modularity\u003c\/td\u003e\n\u003ctd\u003e6 channels \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Input Types \u0026amp; Resolution\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBipolar current: +\/- 20 mA (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eBipolar voltage: +\/- 10 V (16 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eBipolar voltage: +\/- 5 V (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar current: 0...20 mA (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar offset current: 4...20 mA (14 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar offset voltage: 1...5 V (14 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar voltage: 0...10 V (16 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar voltage: 0...5 V (15 bits DC) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAbsolute Maximum Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 25 mA current \/ +\/- 50 V voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm voltage \/ \u0026gt; 250 Ohm current \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB 50\/60 Hz input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUpdate Time (Input)\u003c\/td\u003e\n\u003ctd\u003e320 ms input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Number\u003c\/td\u003e\n\u003ctd\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Range\u003c\/td\u003e\n\u003ctd\u003e4...20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003e7...30 V DC output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLoop Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e0...60 V DC with external resistance output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e30 V DC 20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSetting Time\u003c\/td\u003e\n\u003ctd\u003e900 µs to +\/- 0.1% of the final value output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUpdate Time (Output)\u003c\/td\u003e\n\u003ctd\u003e15 ms output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Demands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e5 input words \/ 2 output words \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e350 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy \u0026amp; Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute Accuracy Error\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.03% at 25 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.20% of full scale at 25 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.05% of full scale max at 25 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.004% of full scale at 0...60 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOffset Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-0.0014 % of full scale max\/degC 0...60 degC input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eGain Shift\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 0.002 of full scale max 0...60 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.007 %\/degC of full scale max at 0...60 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute \/ 750 V DC for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChannel to Bus Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute \/ 750 V DC for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput to Output Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V for 1 minute \/ 750 V for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% without condensation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmbient Air Temp (Operation)\u003c\/td\u003e\n\u003ctd\u003e0...60 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmbient Air Temp (Storage)\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIndicator \/ Terminal Status\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Active LED (Green)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates active backplane bus communication is present \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Fault LED (Red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates an external fault condition has been detected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Active LEDs (6x Green)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually indicates that the corresponding channel is turned on \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Fault LEDs (6x Red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually indicates an active fault on the corresponding channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Placement\u003c\/strong\u003e: Mount the standard format module within a verified Modicon Quantum rack slot. Ensure proper retention screws are fastened to resist mechanical stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Connection\u003c\/strong\u003e: Secure an external power supply ranging from 7...30 V DC to drive the analog output circuit loops effectively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Use twisted-pair shielded cables for analog signal line routing. Ground the shields according to standard engineering practices to optimize common mode rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Thresholds\u003c\/strong\u003e: Ensure ambient air temperatures remain between 0 and 60 degC during active system operation, with relative humidity held below 95% without condensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No 142, UL 508 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: CE, C-Tick.1, FM Class 1 Division 2 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Field Resistance\u003c\/strong\u003e: 10 V\/m 80...2000 MHz conforming to IEC 801-3 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSustainability \u0026amp; Directives\u003c\/strong\u003e: Green Premium product, RoHS compliant (since date code 0842 Schneider Electric declaration of conformity), REACH reference not containing SVHC above the designated threshold \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific fault types can the diagnostic circuit paths register?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module detects an open circuit condition on both the input and output lines, an overtracking scale error on unipolar input loops, and updates the dedicated status byte for output parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the built-in filtering circuit on this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach input incorporates a single-pole low-pass filter providing an attenuation of -3 dB at 21 Hz (+\/- 20%) to damp high-frequency electrical noise before signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the analog output section draw its operating voltage directly from the backplane bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the module requires 350 mA from the backplane bus for internal processing, the analog output loop requires an independent external power connection supplying 7...30 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the isolation parameters between the input and output sides of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal dielectric boundaries provide continuous isolation rated up to 500 V AC or 750 V DC for 1 minute between the input channels and output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104522494315,"sku":"140AMM09000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140amm09000-ahxygsogmnz.png?v=1776159463","url":"https:\/\/www.plcprotech.com\/products\/schneider-electric-140amm09000-modicon-quantum-analog-input-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}