{"product_id":"schneider-electric-140cpu67060-modicon-quantum-unity-hot-standby-processor","title":"Schneider Electric 140CPU67060 Modicon Quantum Unity Hot Standby Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003eUnity processor\u003c\/strong\u003e is designed for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e to provide high-availability control through \u003cstrong\u003eHot Standby\u003c\/strong\u003e functionality. Operating at a clock frequency of \u003cstrong\u003e266 MHz\u003c\/strong\u003e, the module features an onboard memory of \u003cstrong\u003e512 KB\u003c\/strong\u003e dedicated for data RAM, with support for expandable program and file storage via PCMCIA cards.\u003c\/p\u003e\n\u003cp\u003eThe processor facilitates robust system distribution, managing up to \u003cstrong\u003e63 distributed I\/O stations\u003c\/strong\u003e and up to \u003cstrong\u003e6 Ethernet X80 remote I\/O racks (racks supporting up to 6 drops)\u003c\/strong\u003e. Local discrete and analogue I\/O configurations are explicitly restricted in Hot Standby setups to preserve system architecture integrity. Integrated communication capabilities feature multiple connection types including a dedicated \u003cstrong\u003emultimode fiber optic port\u003c\/strong\u003e utilizing the Hot Standby protocol, along with dedicated ports for \u003cstrong\u003eModbus\u003c\/strong\u003e, \u003cstrong\u003eModbus Plus\u003c\/strong\u003e, and \u003cstrong\u003eUSB\u003c\/strong\u003e connections. It is optimized for high-reliability \u003cstrong\u003eprocess control\u003c\/strong\u003e and automated verification checks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Availability Hot Standby\u003c\/strong\u003e: Features an integrated MT-RJ multimode fiber optic interface running a dedicated Hot Standby protocol to synchronize primary and secondary controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Memory Architecture\u003c\/strong\u003e: Provides 512 KB of internal data RAM, with expansion capabilities up to 8 MB for file storage and 7168 kB for application programs using PCMCIA cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Execution\u003c\/strong\u003e: Performs operations with an execution time of 0.0525...0.075 µs for Boolean instructions and 0.4...0.5 µs for floating-point calculations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Networking Range\u003c\/strong\u003e: Supports up to 3 local networks each for Modbus Plus, Ethernet TCP\/IP, and Profibus DP, alongside remote and distributed AS-Interface mapping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Rack Compatibility\u003c\/strong\u003e: Designed to operate within standard Modicon Quantum mounting structures, aligning with system setups from 2 to 16 slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Task Management\u003c\/strong\u003e: Formatted to execute 1 cyclic\/periodic master task, optimized specifically for deterministic process environment requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant power plant control systems\u003c\/li\u003e\n\u003cli\u003eContinuous chemical and petrochemical processing\u003c\/li\u003e\n\u003cli\u003eHigh-availability water and wastewater treatment facilities\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure and environmental monitoring\u003c\/li\u003e\n\u003cli\u003eLarge-scale industrial distributed I\/O installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e266 MHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Boolean)\u003c\/td\u003e\n\u003ctd\u003e0.0525...0.075 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Word)\u003c\/td\u003e\n\u003ctd\u003e0.045...0.06 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Fixed-Point)\u003c\/td\u003e\n\u003ctd\u003e0.045...0.06 μs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Floating-Point)\u003c\/td\u003e\n\u003ctd\u003e0.4...0.5 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNumber of Instructions per ms\u003c\/td\u003e\n\u003ctd\u003e20 Kinst\/ms (100% Boolean) \/ 15 Kinst\/ms (65% Boolean, 35% numerical) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSystem Overhead\u003c\/td\u003e\n\u003ctd\u003e1 ms master task \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal RAM Description\u003c\/td\u003e\n\u003ctd\u003e512 KB for data \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExpandable Program Memory\u003c\/td\u003e\n\u003ctd\u003eUp to 7168 kB with PCMCIA card \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExpandable File Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 8 MB with PCMCIA card \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSwitch Function\u003c\/td\u003e\n\u003ctd\u003eKey switch memory port on\/off \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity \u0026amp; Routing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e10, 16, 2, 4, 6 (rack-dependent) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNumber of Racks\u003c\/td\u003e\n\u003ctd\u003e2-local rack(s) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDistributed I\/O Stations\u003c\/td\u003e\n\u003ctd\u003e63 station(s) 1 rack(s) - 3 Modbus Plus network(s) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Stations\u003c\/td\u003e\n\u003ctd\u003e6-2 ethernet X80 remote I\/O rack(s) (Up to 6 drops X80) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDiscrete \/ Analogue I\/O Limits\u003c\/td\u003e\n\u003ctd\u003e0-local (forbidden in Hot Standby application) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDistributed I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e8000 inputs, 8000 outputs \/ 500 inputs, 500 outputs per Modbus Plus network \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eApplication Specific I\/O\u003c\/td\u003e\n\u003ctd\u003eAccurate time stamping, Counter, High-speed interrupt inputs, Serial link \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e2500 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e1 LED red for Ethernet collision \/ 1 LED green for Ethernet activity (COM) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDimensions (Supported Racks)\u003c\/td\u003e\n\u003ctd\u003e290 mm Height; width varying from 104 mm to 671 mm based on 2 to 16 slot configurations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Connector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMT-RJ Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Multimode fiber optic port running Hot Standby protocol for primary\/secondary PLC interconnection up to 4 km \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Dedicated connection port for Modbus bus communication \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSUB-D 9 Female Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Dedicated connection port for Modbus Plus network interfacing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated connection type for local diagnostic and programming access \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Redundancy Interconnection\u003c\/strong\u003e: Connect the primary and secondary processors using standard MT-RJ multimode fiber optic cabling. The architecture supports a maximum physical length of up to 4 km between the paired controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Restrictions\u003c\/strong\u003e: Mount the processor securely into a compatible Modicon Quantum automation platform slot. Note that auxiliary tasks, timer interrupt tasks, standard interrupt tasks, I\/O interrupt tasks, and periodic fast tasks are explicitly forbidden when running a Hot Standby application configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Protection\u003c\/strong\u003e: Utilize the onboard functional hardware key switch to toggle the memory port on or off, protecting the configured data and program blocks from unauthorized local modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segregation\u003c\/strong\u003e: Ensure proper termination on the Modbus Plus SUB-D 9 network line and monitor diagnostic LEDs to avoid communication collisions or packet losses across local paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: CE, CSA, GOST, UL, Misc (Marine) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: HazLoc \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSustainability \u0026amp; Directives\u003c\/strong\u003e: Green Premium product, RoHS compliant (since date code 1111 via Schneider Electric declaration of conformity), REACH reference not containing SVHC above the designated threshold \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the fiber optic port located on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MT-RJ multimode fiber optic interface is dedicated to running the integrated Hot Standby protocol, synchronizing primary and secondary processors over distances up to 4 km for seamless process control backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre local I\/O cards permitted in the same rack as the processor during redundant operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Local discrete and analogue I\/O configurations are forbidden when the processor is implemented within a Hot Standby system topology. All I\/O must be routed through distributed networks or Ethernet remote drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is program memory expanded if the 512 KB data RAM is insufficient for full applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accommodates hardware memory expansion via PCMCIA cards, supporting up to 7168 kB for program storage and up to 8 MB for general file storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the integrated diagnostic LEDs on the faceplate indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe faceplate includes two distinct LED status indicators: a red LED that alerts the operator to an active Ethernet collision and a green LED that indicates ongoing Ethernet communication activity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695219798379,"sku":"140CPU67060","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-140cpu67060-cpu-single-slot-module-o0yn4ma0whp_5466774c-a84c-465c-b79c-6cff29a3bf2f.jpg?v=1766131065","url":"https:\/\/www.plcprotech.com\/products\/schneider-electric-140cpu67060-modicon-quantum-unity-hot-standby-processor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}