{"product_id":"schneider-electric-bmxcps3020h-modicon-x80-harsh-environment-power-supply-module","title":"Schneider Electric BMXCPS3020H Modicon X80 Harsh Environment Power Supply Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding reliable, isolated backplane power under extreme thermal and chemical conditions, the \u003cstrong\u003eSchneider Electric BMXCPS3020H\u003c\/strong\u003e serves as a ruggedized power supply module for the Modicon X80 platform. This module is engineered specifically for harsh environments, delivering stable DC power to the CPU, I\/O modules, and application-specific modules mounted on the backplane rack.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Enhanced protection against corrosive atmospheres, chemical agents, and high humidity (compliant with ISA S71.04 class G3).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide DC Input Range:\u003c\/strong\u003e Operates on a nominal 24V to 48V DC input with a wide tolerance band to handle voltage fluctuations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Backplane Outputs:\u003c\/strong\u003e Supplies both 3.3V DC and 24V DC power directly to the rack backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Front-panel LED indicators provide real-time status of input voltage presence and output power integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Protection:\u003c\/strong\u003e Built-in short-circuit, overvoltage, and overload protection safeguards downstream rack components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eWater and wastewater treatment facilities exposed to corrosive gases.\u003c\/li\u003e\n  \u003cli\u003eOil and gas extraction platforms and refining operations.\u003c\/li\u003e\n  \u003cli\u003eChemical processing plants and heavy manufacturing environments.\u003c\/li\u003e\n  \u003cli\u003eOutdoor control cabinets subject to extreme seasonal temperature variations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBMXCPS3020H\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModicon X80 \/ M340\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNominal Input Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V to 48 V DC (isolated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e19.2 V to 62.4 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.65 A at 24 V DC \/ 0.83 A at 48 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTotal Output Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e31.2 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBackplane Output 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3.3 V DC at 1.5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBackplane Output 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC at 1.0 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eIsolation Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u0026gt; 100 MOhm at 500 V DC (primary to secondary)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 degC to +70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEnvironmental Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConformal coating (ISA S71.04 class G3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.49 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e15.9 x 15.7 x 13.8 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eTerminal \/ Pin\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunction Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e24-48V DC (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePositive DC supply input connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e0V DC (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNegative DC supply input connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProtective Earth (Ground) connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNC \/ NO \/ COM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eVolt-free alarm relay contacts for power status monitoring\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe BMXCPS3020H is the direct, conformal-coated equivalent of the standard BMXCPS3020 module. It shares identical electrical output ratings and physical form factors, allowing it to drop directly into any standard Modicon X80 backplane slot. When upgrading from a standard module to the \"H\" variant, no software configuration changes are required in EcoStruxure Control Expert (formerly Unity Pro).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile the conformal coating protects the internal circuitry from corrosive gases and moisture, this module must still be installed within an enclosure that provides the appropriate IP rating for the local environment. Ensure that total power consumption of all modules on the backplane does not exceed the 31.2W threshold, particularly when using high-density analog modules or communication coprocessors.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor optimal noise immunity, use a dedicated, low-impedance grounding strap from the PE terminal directly to the cabinet ground bus. Avoid routing the DC input power lines parallel to high-voltage AC motor cables to prevent induced transient noise on the backplane power rails.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING: ELECTRICAL SHOCK AND EQUIPMENT DAMAGE\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eDisconnect all power sources before installing, removing, or wiring this module. Do not hot-swap the power supply module while the backplane is energized, as this can cause electrical arcing and permanent damage to the backplane contacts and adjacent CPU or I\/O modules.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eEnsure the rack power source is completely de-energized and locked out following standard industrial safety protocols.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eLocate the dedicated power supply slot on the far left of the Modicon X80 backplane (Slot 0).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eAlign the module with the guide slots, press firmly until the module is fully seated on the backplane connector, and tighten the mounting screw to secure it to the rack.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eWire the 24-48V DC input and ground connections to the terminal block using the specified wire gauge (typically 1.5 mm2 to 2.5 mm2) and torque specifications.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104552214891,"sku":"BMXCPS3020H","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bmxcps3020h-zx0soo5dgjo.png?v=1776162896","url":"https:\/\/www.plcprotech.com\/products\/schneider-electric-bmxcps3020h-modicon-x80-harsh-environment-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}