{"product_id":"schneider-electric-lx1fl110-tesys-f-contactor-coil","title":"Schneider Electric LX1FL110 TeSys F Contactor Coil","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLX1FL110\u003c\/strong\u003e is a replacement control coil designed specifically for the \u003cstrong\u003eTeSys F contactor LC1-F630\u003c\/strong\u003e. This coil is engineered for reliable operation at a supply voltage of \u003cstrong\u003e110\/120 V AC\u003c\/strong\u003e across a frequency range of \u003cstrong\u003e40-400 Hz\u003c\/strong\u003e. As a critical component for contactor maintenance and repair, this coil ensures the precise electromechanical actuation required for high-power switching applications in industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for TeSys F contactor model \u003cstrong\u003eLC1-F630\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 110\/120 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 40-400 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Actuation coil for contactor switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Robust design suitable for industrial electrical cabinet environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMaintenance and repair of TeSys F contactor systems\u003c\/li\u003e\n\u003cli\u003eReplacement of worn or damaged contactor coils\u003c\/li\u003e\n\u003cli\u003eIndustrial motor control and power distribution panels\u003c\/li\u003e\n\u003cli\u003eAutomation systems requiring high-power switching contactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eTeSys D (TeSys F series compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContactor Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e110\/120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e40-400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.50 cm x 12.00 cm x 10.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.47 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e Ensure the power supply is completely isolated and locked out before attempting to replace the coil in the LC1-F630 contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess:\u003c\/strong\u003e Open the contactor housing to access the coil assembly, following the specific disassembly instructions provided in the contactor’s service manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement:\u003c\/strong\u003e Carefully remove the old coil and slide the new \u003cstrong\u003eLX1FL110\u003c\/strong\u003e coil into place, ensuring the magnetic core and springs are correctly aligned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Secure the control wiring to the coil terminals, ensuring tight, vibration-resistant connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e After reassembly, verify the contactor’s operation by applying the rated control voltage to ensure smooth engagement and disengagement of the main contacts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104560210283,"sku":"LX1FL110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/lx1fl110-nu5axvrrw05.png?v=1776163283","url":"https:\/\/www.plcprotech.com\/products\/schneider-electric-lx1fl110-tesys-f-contactor-coil","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}