{"product_id":"schneider-electric-tm241ce24t-modicon-m241-logic-controller","title":"Schneider Electric TM241CE24T Modicon M241 Logic Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDesigned to manage high-performance machine control architectures, the \u003cstrong\u003eSchneider Electric TM241CE24T\u003c\/strong\u003e serves as a central processing unit within the \u003cstrong\u003eModicon M241\u003c\/strong\u003e logic controller family, delivering embedded Ethernet and CANopen connectivity alongside high-speed transistor I\/O. This controller provides machine builders with scalable, efficient control for complex applications requiring coordinated motion and distributed fieldbus communication.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density I\/O Configuration:\u003c\/strong\u003e Equipped with 24 integrated channels, comprising 14 discrete inputs (including 8 fast inputs) and 10 source (PNP) transistor outputs (including 4 fast outputs).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Communication Suite:\u003c\/strong\u003e Features embedded Ethernet (RJ45), CANopen master (SUB-D 9), a non-isolated serial link (RJ45), and a USB mini-B programming port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e Supports high-speed counter (HSC) functions up to 200 kHz and pulse train outputs (PTO) for precise positioning tasks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Expandability:\u003c\/strong\u003e Compatible with Modicon TM3 expansion modules, allowing local and remote I\/O scaling without compromising processing speed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Housed in a compact, DIN-rail mountable enclosure designed to withstand harsh electromagnetic and thermal conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Controls wrapping, cartoning, and labeling systems requiring fast sensor registration and precise actuator response.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling \u0026amp; Conveying:\u003c\/strong\u003e Manages sorting systems, multi-axis conveyors, and automated guided vehicle (AGV) routing interfaces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePumping and Fluid Control:\u003c\/strong\u003e Integrates with variable speed drives via CANopen or Modbus TCP to regulate pressure, flow, and level controls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecialized Machine Tools:\u003c\/strong\u003e Executes multi-axis motion profiles and coordinates auxiliary tooling systems in manufacturing cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTM241CE24T\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eModicon M241\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDiscrete Input Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e14 (conforming to IEC 61131-2 Type 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDiscrete Input Logic\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSink or Source (positive\/negative)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDiscrete Output Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10 Transistor (including 4 fast outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDiscrete Output Logic\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSource (PNP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDiscrete Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 24 V DC\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDiscrete Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.5 A for transistor output (0.1 A for fast output)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMemory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8 MB for program, 64 MB for system RAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProgramming Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eEcoStruxure Machine Expert (SoMachine)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-10 to 50 degC (vertical installation); -10 to 55 degC (horizontal installation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e150 mm x 90 mm x 95 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.64 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIndonesia\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eConnector \/ Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRJ45 (10\/100 Mbit\/s)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eModbus TCP Client\/Server, EtherNet\/IP adapter, Web Server, and programming\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCANopen Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSUB-D 9-pin male\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCANopen Master interface for distributed drives and remote I\/O islands\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSerial Link\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRS232 \/ RS485 serial communication (Modbus RTU \/ ASCII Master or Slave)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUSB Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUSB mini-B\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDedicated local programming and firmware download interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Supply Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRemovable Screw Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC main power input (+ \/ - \/ Functional Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe TM241CE24T is a direct functional upgrade from legacy Twido and Modicon M221 controllers. Note that unlike the M221 series which uses EcoStruxure Machine Expert Basic, the M241 series requires the full licensed version of \u003cstrong\u003eEcoStruxure Machine Expert\u003c\/strong\u003e. When migrating programs, I\/O mapping must be updated to reflect the specific hardware addresses of the TM241CE24T, particularly the high-speed counter (HSC) configurations.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nBecause the 10 digital outputs are \u003cstrong\u003esource (PNP) transistor\u003c\/strong\u003e types, they switch the positive 24 V DC rail to the load. Connecting these outputs to sink-configured (NPN) inputs on downstream devices will result in a non-functional signal path and potential reverse-bias damage if not isolated via interposing relays. Additionally, ensure that the total current drawn across all outputs does not exceed the 2.0 A common limit to prevent thermal shutdown of the output driver IC.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nTo ensure reliable CANopen communication, always install a 120-Ohm terminating resistor at both physical ends of the CAN trunk line. For high-speed counter (HSC) inputs, use shielded twisted-pair (STP) cabling and terminate the shield to the functional ground (FG) bar immediately adjacent to the controller. This practice minimizes high-frequency electromagnetic interference from nearby variable frequency drives (VFDs).\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: ELECTRICAL HAZARD\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources before mounting, wiring, or removing the controller. Verify that the 24 V DC external power supply is switched off and locked out. Failure to follow these precautions can result in severe electrical shock, equipment damage, or unexpected machine startup.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the controller horizontally on a standard 35 mm DIN rail inside a well-ventilated, IP54-rated industrial enclosure. Maintain at least 50 mm of clearance above and below the unit for convective cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the functional ground (FG) terminal on the power supply connector directly to the main protective earth (PE) ground bar using a copper wire with a minimum cross-section of 1.5 mm² (16 AWG).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the 24 V DC power supply to the removable terminal block. Ensure correct polarity to avoid triggering the internal reverse-polarity protection circuit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the RJ45 Ethernet cable into the dedicated port. Ensure the cable is rated Cat5e shielded or higher to maintain communication integrity in high-noise environments.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104525148523,"sku":"TM241CE24T","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tm241ce24t-bnv13oxcuki.png?v=1776163555","url":"https:\/\/www.plcprotech.com\/products\/schneider-electric-tm241ce24t-modicon-m241-logic-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}