{"product_id":"schneider-electric-tsx3708001-modicon-tsx-micro-plc-base-controller","title":"Schneider Electric TSX3708001 Modicon TSX Micro PLC Base Controller","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for compact industrial automation architectures, the Schneider Electric TSX3708001 serves as a modular base controller within the Modicon TSX Micro platform. This hardware platform provides localized control, processing, and input\/output management for medium-complexity machine automation and process loops. By utilizing a \u003cstrong\u003emodular slot configuration\u003c\/strong\u003e, the unit allows control engineers to scale system capabilities through the integration of specialized discrete, analog, and communication modules.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e Features 2 available slots to accommodate half-format or full-format Modicon TSX Micro I\/O and application-specific modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Power Supply:\u003c\/strong\u003e Operates on a nominal 24V DC input, simplifying cabinet power distribution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpandable Memory:\u003c\/strong\u003e Includes a PCMCIA slot for memory expansion cards, ensuring sufficient capacity for complex logic and data logging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Communication:\u003c\/strong\u003e Equipped with a dedicated Ter port for direct connection to programming terminals, HMIs, or serial networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Industrial-grade housing designed to withstand vibration, thermal stress, and electrical noise in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eMaterial handling and automated conveyor sorting systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and assembly line control.\u003c\/li\u003e\n  \u003cli\u003eWater treatment pumping stations and localized environmental control.\u003c\/li\u003e\n  \u003cli\u003eLegacy system upgrades and drop-in replacements for existing Modicon TSX Micro architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTSX3708001\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModicon TSX Micro\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDevice Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModular Base Controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 Slots (for I\/O or communication modules)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProgramming Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePL7 Micro \/ PL7 Pro\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eObsolete \/ Legacy\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16.40 x 14.20 x 7.40 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.54kg;\"\u003e0.54 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85371099\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eInterface Port \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24V DC main power input and system ground connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTER Port (Mini-DIN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUni-Telway programming terminal, HMI interface, or serial link\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePCMCIA Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMemory expansion card or network communication card interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe TSX3708001 is a legacy hardware component. When replacing this unit in existing systems, ensure that the application program compiled in PL7 Micro\/Pro is fully backed up. If migrating to modern platforms, the Modicon M340 or M241 series serves as the recommended upgrade path, though this requires a complete rewrite of the control logic within EcoStruxure Control Expert or Machine Expert.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure adequate thermal management inside the enclosure. Because this unit relies on natural convection cooling, maintaining a minimum clearance of 50 mm above and below the chassis is critical. Operating the controller in ambient temperatures exceeding 60 degC without active ventilation will accelerate component degradation and may lead to unexpected CPU faults.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use high-quality shielded cabling for the TER port connection to mitigate electromagnetic interference (EMI) from adjacent variable frequency drives (VFDs). Ensure that the DIN rail mounting clips are fully engaged and that the rail itself is bonded directly to the central cabinet ground busbar to maintain proper noise immunity.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to initiating installation, maintenance, or module insertion, completely de-energize the main cabinet power supply. Verify that no residual voltage is present on the 24V DC terminal block. Failure to isolate power can result in permanent damage to the CPU backplane and connected I\/O modules.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eMount the TSX3708001 base controller horizontally onto a standard 35 mm DIN rail, ensuring the locking latch securely clicks into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eConnect the functional ground wire to the dedicated grounding terminal on the base unit using a low-impedance conductor.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eInsert any required expansion modules into the designated slots, ensuring they are fully seated and locked before applying power.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"margin: 0;\"\u003eWire the 24V DC power supply to the input terminal block, paying strict attention to correct polarity markings.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104502702443,"sku":"TSX3708001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsx3708001-jyybunkstsk.png?v=1776163644","url":"https:\/\/www.plcprotech.com\/products\/schneider-electric-tsx3708001-modicon-tsx-micro-plc-base-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}