{"product_id":"schneider-modicon-premium-tsxdsy16r5c-digital-output-module","title":"Schneider Modicon Premium TSXDSY16R5C Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXDSY16R5C\u003c\/strong\u003e is a \u003cstrong\u003eModicon Premium discrete output module\u003c\/strong\u003e featuring 16 relay outputs designed for robust signal switching in industrial control applications. This module operates within a voltage range of 12 V DC to 24 V DC and supports switching loads up to 3 A per channel. The relay-based architecture provides galvanic isolation between the controller and the field devices, making it highly effective for driving various actuators, contactors, and solenoids in legacy Modicon Premium automation systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay-based digital outputs\u003c\/li\u003e\n\u003cli\u003eRated operational voltage: 12-24 V DC\u003c\/li\u003e\n\u003cli\u003eSwitching capacity: 3 A per channel\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for enhanced signal integrity\u003c\/li\u003e\n\u003cli\u003eDesigned for the Modicon Premium automation platform\u003c\/li\u003e\n\u003cli\u003eReliable switching for diverse industrial loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial automation process control\u003c\/li\u003e\n\u003cli\u003eActuator and solenoid valve management\u003c\/li\u003e\n\u003cli\u003eContactor control in automation panels\u003c\/li\u003e\n\u003cli\u003eSignal interfacing for field instrumentation\u003c\/li\u003e\n\u003cli\u003eLogic control implementation in complex systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay (not protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e12 - 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e3 A (per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely insert the module into the designated slot on the Modicon Premium rack. Ensure the backplane interface is correctly aligned and locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field devices to the relay output terminals. Due to the relay nature of the outputs, ensure current limits are respected to prevent contact welding or degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Because these outputs are not internally protected, it is highly recommended to install external fusing or surge suppression devices (such as RC networks or flyback diodes) to protect the relay contacts from inductive load transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Verify that the system power is disconnected before performing any maintenance or wiring modifications to the module terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain the rack in an environment free from excessive vibration, heat, and conductive particulates to ensure stable relay operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573088107,"sku":"TSXDSY16R5C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxdsy16r5c-wlpuwqcvimi.png?v=1776163982","url":"https:\/\/www.plcprotech.com\/products\/schneider-modicon-premium-tsxdsy16r5c-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}