{"product_id":"schneider-modicon-premium-tsxispy121-isp-plus-weighing-module","title":"Schneider Modicon Premium TSXISPY121 ISP Plus Weighing Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXISPY121\u003c\/strong\u003e functions as a high-precision \u003cstrong\u003eISP Plus weighing module\u003c\/strong\u003e developed for integration within the \u003cstrong\u003eModicon Premium Automation platform\u003c\/strong\u003e. This specialized hardware subassembly executes rapid industrial weight data acquisition, supporting processing rates of up to 50 measurements per second. The device features a single measurement input channel with an analogue input resolution of 20 bits, translating to an internal capacity of 1,048,857 points. Designed to supply stabilized power directly to connected sensors, it outputs a constant 10 V DC sensor power supply to drive external field components.\u003c\/p\u003e\n\u003cp\u003eFor localized process adjustments, the hardware incorporates \u003cstrong\u003ediscrete reflex\u003c\/strong\u003e outputs with a rapid response time of 1 ms, handling positive switching states up to 500 mA at 24 V DC. Communication infrastructure is facilitated by an unisolated RS485 serial link operating at a transmission rate of 9.6 kbit\/s, enabling dedicated connection paths directly to a Magelis weight indicator. This architecture makes the module highly suitable for industrial batching, filling, and dynamic crane or hopper weighing procedures across modern production lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion\u003c\/strong\u003e: Employs a 20-bit internal analog-to-digital converter achieving a total resolution of 1,048,857 points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measuring Frequency\u003c\/strong\u003e: Executes up to 50 discrete weight measurements per second for responsive automation tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Reflex Outputs\u003c\/strong\u003e: Provides 2 positive reflex outputs with an ultra-low response time of 1 ms for precise batch cutoff control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Sensor Power Management\u003c\/strong\u003e: Supplies an onboard 10 V DC power path dedicated exclusively to attached bridge load cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Serial Bus\u003c\/strong\u003e: Features a built-in unisolated RS485 serial link optimized for dedicated remote weight indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Premium Form Factor\u003c\/strong\u003e: Built to fit seamlessly into standard Modicon Premium rack slot allocations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial container and silo hopper weight monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-speed automated batching and formula blending systems\u003c\/li\u003e\n\u003cli\u003eMaterial packaging, bagging, and inline check-weighing machinery\u003c\/li\u003e\n\u003cli\u003eCrane overload protection and heavy material handling tracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (LC Schneider) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTSXISPY121 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISP Plus weighing module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Measurement Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Input Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 bits (1048576 points) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurements per second \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MOhm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad cell 1...8 350 Ohm yes \u0026lt;= 300 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete reflex 2 positive \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time on Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s RS485 non isolated \u0026lt;= 30 m discrete reflex weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Division\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 uV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Cable Distance Between Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 m for module\/weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mA at 24 V rack \/ 150 mA at 5 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...95% non-condensing (operation) \/ 5...95% non-condensing (storage) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...2000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Interface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 connector screw terminal block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUsed for connecting 2 discrete reflex outputs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 female connector SUB-D 15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated for the indicator input lines \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 female connector SUB-D 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides the RS485 serial link connection to the weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eRack Placement and Insertion\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the primary rack power supply of the Modicon Premium automation platform is switched off before inserting or extracting the hardware.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly along the structural chassis alignment paths until the rear terminal contacts mate completely into the active rack bus lines.\u003c\/li\u003e\n\u003cli\u003eTighten the integrated faceplate screws to confirm grounding and safeguard against vibration displacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Length and Isolation Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKeep the interconnection distance between the main weighing block and the dedicated remote weight indicator below the specified 3 m distance boundary to avoid transmission losses.\u003c\/li\u003e\n\u003cli\u003eWhen implementing field extensions for the load cell inputs, ensure the maximum shielding run does not exceed 300 m.\u003c\/li\u003e\n\u003cli\u003eRun all low-voltage analog load cell sensor cabling inside isolated trays, separated completely from primary high-current AC machinery power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE \u003c\/li\u003e\n\u003cli\u003eSDM No 97.06 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat parameters govern the sensor compatibility for this weighing module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe module is designed to interface seamlessly with standard strain-gauge load cells, supporting configurations ranging from 1 to 8 parallel load cells with a nominal bridge resistance of 350 Ohm up to a maximum distance boundary of 300 m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary electrical draws exerted by this unit on the main rack assembly?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe device pulls electrical current across two distinct voltage rails provided by the Modicon backplane, consuming 145 mA at the 24 V rack supply line while simultaneously drawing 150 mA from the localized 5 V DC internal distribution rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the direct physical reflex output channels bound to external switching loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e External loops hook directly into the integrated terminal interface using a dedicated single connector screw terminal block layout, which distributes the two positive 24 V DC reflex switching points out to localized relays or indicators.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573219179,"sku":"TSXISPY121","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxispy121-muccmmkuu2c.png?v=1776164103","url":"https:\/\/www.plcprotech.com\/products\/schneider-modicon-premium-tsxispy121-isp-plus-weighing-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}