{"product_id":"schneider-tsxsay1000c-coated-as-interface-master-module","title":"Schneider TSXSAY1000C Coated AS-Interface Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized AS-Interface (AS-i) Master Module designed for the Schneider Electric Modicon Premium automation platform. This \"C\" version is characterized by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating (Humiseal 1A33)\u003c\/strong\u003e, which provides superior protection against moisture, dust, and chemical contaminants, making it ideal for harsh industrial environments. Operating as a bridge between the Modicon Premium rack and the AS-i cabling system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV2 standard and extended addressing\u003c\/strong\u003e, allowing for a highly flexible and scalable network of actuators and sensors. By simplifying field wiring into a single two-wire cable for both power and data, this module significantly reduces installation costs and improves diagnostic capabilities in complex automated systems such as bottling plants, conveyor networks, and specialized machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXSAY1000C is engineered for high-density networking and robust environmental performance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAS-i V2 Capabilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports the M2E profile, enabling the management of standard slaves as well as extended addressing slaves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlave Capacity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 31 slaves (Analog I\/O, Discrete 4I\/4O, or Safety interfaces).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 62 slaves (Discrete 4I\/3O), significantly increasing the network's point density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTreated with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHumiseal 1A33\u003c\/strong\u003e, ensuring long-term reliability in corrosive atmospheres or high-humidity zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHost Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowered directly via the Modicon Premium backplane (450 mA at 5 V DC), eliminating the need for external module power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Diversity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of interfacing with a variety of modules including safety-rated interfaces and analog I\/O units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Physical Layer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 3-way male SUB-D connector for secure and reliable connection to the AS-i bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXSAY1000C (Coated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAS-i Version\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV2 (Standard and Extended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e[AS-i] M2E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtective Treatment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Humiseal 1A33)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0…60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Modules (TSX574+)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 per base controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many modules can I install in a TSX57310 processor rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the TSX573 series, the system supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAS-i master modules per base controller. This allows for massive decentralized I\/O scaling within a single PLC project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"C\" designation in TSXSAY1000C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated\u003c\/strong\u003e. While the standard TSXSAY1000 is suitable for clean industrial environments, the TSXSAY1000C is designed for \"Harsh\" environments where airborne pollutants or humidity could otherwise cause short circuits or corrosion on the PCB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide power to the AS-i bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the module takes its own logic power (450 mA) from the Premium rack, the AS-i bus itself requires a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAS-i Power Supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(usually 30 V DC with integrated data decoupling) to power the field sensors and actuators.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAddressing and Commissioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen using extended addressing (V2), ensure that your slaves are also V2 compliant. Extended addressing divides the standard 31 addresses into \"A\" and \"B\" banks, allowing for 62 total devices. Use the local signaling display unit on the front of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto identify address conflicts or bus faults during the initial power-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and SUB-D Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3-way SUB-D connector is the primary gateway to the AS-i bus. Use high-quality, shielded AS-i yellow flat cable for the field run. Ensure that the total cable length does not exceed 100 meters without the use of AS-i repeaters. Even with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHumiseal 1A33 coating\u003c\/strong\u003e, ensure the SUB-D connector is firmly tightened to maintain a gas-tight seal at the connection point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 rating means the module must be installed in an enclosure. Because this is the coated version, it is specifically intended for cabinets located in \"Class 3C2\" or similar environments. Maintain a vertical mounting orientation to facilitate natural convection, as the module consumes nearly 2.25 Watts of power from the backplane, which must be dissipated to stay within the 0…60 °C operating range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573809003,"sku":"TSXSAY1000C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxsay1000c-qe1acipseoe.png?v=1776164526","url":"https:\/\/www.plcprotech.com\/products\/schneider-tsxsay1000c-coated-as-interface-master-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}