{"product_id":"siemens-6ag1503-3cb00-2aa0-siplus-net-olm-g12-v4-0-optical-link-module","title":"Siemens 6AG1503-3CB00-2AA0 SIPLUS NET OLM\/G12 V4.0 Optical Link Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6AG1503-3CB00-2AA0\u003c\/strong\u003e is a ruggedized \u003cstrong\u003eSIPLUS NET OLM\/G12 V4.0\u003c\/strong\u003e industrial optical link module designed for PROFIBUS networks in harsh environments. Based on the standard 6GK1503-3CB00, this variant features a specialized conformal coating to protect electronic components against chemical, mechanical, and biological influences. It facilitates reliable data transmission over fiber-optic cables, ensuring consistent communication in industrial automation systems. This module is engineered to maintain process stability and system uptime across a broad operational temperature range, making it suitable for demanding production infrastructure and long-distance communication links.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConformal coating for enhanced environmental protection\u003c\/li\u003e\n\u003cli\u003eOperational temperature range: -25 degC to +60 degC\u003c\/li\u003e\n\u003cli\u003eCompatible with existing 6GK1503-3CB00 network architectures\u003c\/li\u003e\n\u003cli\u003eSupports PROFIBUS network topologies\u003c\/li\u003e\n\u003cli\u003eDesigned for robust performance in industrial production environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePROFIBUS fiber-optic network expansion\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and control systems\u003c\/li\u003e\n\u003cli\u003eInfrastructure requiring electromagnetic interference (EMI) immunity\u003c\/li\u003e\n\u003cli\u003eExtended distance communication between PLC and remote I\/O\u003c\/li\u003e\n\u003cli\u003eHarsh environment production facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eConverters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.20 cm x 14.60 cm x 4.80 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is installed in a location with adequate ventilation to maintain operating temperatures within the specified -25 degC to +60 degC range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e The conformal coating provides protection, but avoid direct exposure to caustic substances or extreme moisture beyond standard industrial requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use appropriate fiber-optic cables compatible with the OLM\/G12 V4.0 interface to ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration:\u003c\/strong\u003e Ensure network termination and grounding protocols are followed according to standard PROFIBUS installation practices to prevent ground loops or signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716776653163,"sku":"6AG1503-3CB00-2AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6ag1503-3cb00-2aa0-25hk1hrco40_fbbbd6b8-215e-435c-bbdf-ae3bde8f48fb.jpg?v=1767089388","url":"https:\/\/www.plcprotech.com\/products\/siemens-6ag1503-3cb00-2aa0-siplus-net-olm-g12-v4-0-optical-link-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}