{"product_id":"siemens-6av6642-0da01-1ax0-simatic-hmi-op-177b-pn-dp-operator-panel","title":"Siemens 6AV6642-0DA01-1AX0 SIMATIC HMI OP 177B PN\/DP Operator Panel","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens SIMATIC HMI OP 177B PN\/DP operator panel, part number 6AV6642-0DA01-1AX0, designed for machine-level visualization and control. It features a \u003cstrong\u003e5.7-inch STN color display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e320 x 240 pixels\u003c\/strong\u003e and supports 256 colors. Operator interaction is facilitated through a combination of a resistive \u003cstrong\u003etouchscreen and physical membrane keys\u003c\/strong\u003e. The panel is equipped with a comprehensive set of communication interfaces, including \u003cstrong\u003eMPI\/PROFIBUS-DP\u003c\/strong\u003e, RS485\/RS422, USB, and an integrated \u003cstrong\u003eEthernet port\u003c\/strong\u003e. For data logging and recipe management, it includes a slot for a MultiMediaCard (MM-Card). Configuration and project development for this HMI are performed using WinCC flexible 2005 software.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e5.7-inch STN display with 256-color capability\u003c\/li\u003e\n  \u003cli\u003eDual input method with touchscreen and tactile keys\u003c\/li\u003e\n  \u003cli\u003eIntegrated MPI, PROFIBUS-DP, and Ethernet (PN) interfaces\u003c\/li\u003e\n  \u003cli\u003eSerial communication via RS485 and RS422 ports\u003c\/li\u003e\n  \u003cli\u003eUSB interface for peripheral connection\u003c\/li\u003e\n  \u003cli\u003eExpansion slot for a MultiMediaCard (MM-Card)\u003c\/li\u003e\n  \u003cli\u003e2048 kbyte of available user memory\u003c\/li\u003e\n  \u003cli\u003ePowered by a standard 24V DC supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine control and process monitoring\u003c\/li\u003e\n  \u003cli\u003eFactory and process automation systems\u003c\/li\u003e\n  \u003cli\u003eData entry and visualization at the plant floor level\u003c\/li\u003e\n  \u003cli\u003eStandalone machine operation interfaces\u003c\/li\u003e\n  \u003cli\u003eIntegration into PROFIBUS and PROFINET networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOP 177B PN\/DP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6AV6642-0DA01-1AX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Family\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSIMATIC HMI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperator Panels 170 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSTN, Color\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eScreen Diagonal\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e5.7 inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e320 x 240 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDisplay Colors\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e256\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperator Input\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eTouchscreen and Keys\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUser Memory\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2048 kbyte\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eConfiguration Software\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWinCC flexible 2005\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eInterfaces\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMPI, PROFIBUS-DP, RS485, RS422, USB, Ethernet, Printer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eExpansion Slot\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1 x MM-Card Slot\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSuccessor Part Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6AV6642-0DA01-1AX1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e25.0 x 23.0 x 8.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e5D002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 15px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation, wiring, and maintenance must be performed by qualified personnel only. Failure to comply with safety procedures can result in equipment damage, serious injury, or death. Always de-energize and apply Lockout\/Tagout (LOTO) procedures before accessing electrical components.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePanel Cutout:\u003c\/strong\u003e Prepare the mounting cutout in the enclosure door according to the dimensions specified in the product's installation manual. Ensure all edges are smooth and free of burrs to guarantee a proper seal.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the HMI into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a diagonal pattern to ensure uniform pressure on the gasket for a proper IP rating.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the HMI chassis to the enclosure's main ground point using a short, low-impedance conductor. A proper ground connection is critical for noise immunity and operator safety.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable, protected 24V DC power source to the designated power supply terminals. Verify correct polarity (+\/-) before applying power. Use appropriately sized wiring and ensure the power supply is SELV\/PELV compliant.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e Connect PROFIBUS, Ethernet, and other communication cables to their respective ports. Use shielded, twisted-pair cabling for serial and bus communications. Ensure cable shields are properly terminated at one end to the ground to prevent ground loops. Route communication cables separately from high-voltage power lines.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716768985451,"sku":"6AV6642-0DA01-1AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av6642-0da01-1ax0-314g3elkzgl_fcab8514-995c-4ed3-81c8-5e7e3bc9b14d.jpg?v=1767089111","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av6642-0da01-1ax0-simatic-hmi-op-177b-pn-dp-operator-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}