{"product_id":"siemens-6av7240-0dc06-0ka0-simatic-ipc-477d-panel-pc","title":"Siemens 6AV7240-0DC06-0KA0 SIMATIC IPC 477D Panel PC","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7240-0DC06-0KA0 is a SIMATIC IPC 477D series Panel PC designed for industrial automation and control applications. This unit features a \u003cstrong\u003e19-inch touch display\u003c\/strong\u003e and is powered by an integrated \u003cstrong\u003eCeleron U827E processor\u003c\/strong\u003e. It is configured with \u003cstrong\u003e4 GB of RAM\u003c\/strong\u003e and a \u003cstrong\u003e320 GB SATA HDD\u003c\/strong\u003e for data storage and application hosting. The system comes pre-installed with Windows 7 Ultimate (32-bit) and is equipped with extensive connectivity, including dual Gigabit Ethernet ports and multiple USB interfaces. It operates on a standard \u003cstrong\u003e24 V DC industrial power supply\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e19-inch resistive touch screen interface\u003c\/li\u003e\n  \u003cli\u003eIntegrated Intel Celeron U827E processor\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows 7 Ultimate (32-bit) operating system\u003c\/li\u003e\n  \u003cli\u003eDual Gigabit Ethernet ports for network connectivity (IE\/PN)\u003c\/li\u003e\n  \u003cli\u003eFive USB ports for peripheral device connection\u003c\/li\u003e\n  \u003cli\u003eOne RS-232 serial communication port\u003c\/li\u003e\n  \u003cli\u003eOperates on a 24 V DC industrial power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) for process visualization\u003c\/li\u003e\n  \u003cli\u003eSCADA client stations in manufacturing and processing plants\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging terminals\u003c\/li\u003e\n  \u003cli\u003eMachine control and monitoring in production lines\u003c\/li\u003e\n  \u003cli\u003eIndustrial IT gateways and data concentrators\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC IPC 477D\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e19-inch Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIntel Celeron U827E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4 GB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e320 GB HDD SATA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows 7 Ultimate, 32-bit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2x Gigabit Ethernet (10\/100\/1000 Mbps), IE\/PN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4x Rear, 1x Front\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1x RS-232\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePCIe Slot\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eNot included\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24 V DC Industrial Power Supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6.40 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85371098\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e55 x 45 x 20 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out (LOTO) before commencing work. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Securely mount the Panel PC into a prepared cutout in a NEMA or IP-rated enclosure. Verify that all mounting clamps are tightened evenly to maintain the specified environmental seal. Ensure adequate clearance for ventilation and cable access at the rear of the unit.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis ground terminal to the main protective earth (PE) busbar of the control cabinet using a low-impedance conductor. A proper ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable, filtered 24 V DC power source to the designated power input terminals. Verify correct polarity (+\/-) before energizing. Use appropriately sized wiring and ensure the power supply is capable of handling the PC's inrush and operational current.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eI\/O and Network Cabling:\u003c\/strong\u003e Connect all required communication and peripheral cables (Ethernet, USB, RS-232). Route cables away from high-voltage lines and sources of electromagnetic interference (EMI). Use shielded cables for all data communication where specified.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections, remove the lockout\/tagout device and apply power to the unit. Observe the boot sequence to ensure the operating system loads correctly. Proceed with software configuration and commissioning.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716485345643,"sku":"6AV7240-0DC06-0KA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7240-0dc06-0ka0-fnbafj4rt3q_53409156-8fd5-4ef3-85e7-69d0a9b4237d.jpg?v=1767083368","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7240-0dc06-0ka0-simatic-ipc-477d-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}