{"product_id":"siemens-6av7423-2aa01-0ls0-simatic-hmi-ipc677c-panel-pc","title":"Siemens 6AV7423-2AA01-0LS0 SIMATIC HMI IPC677C Panel PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 16px;\"\u003eThe \u003cstrong\u003eSiemens 6AV7423-2AA01-0LS0\u003c\/strong\u003e is a high-performance industrial workstation designated as a \u003cstrong\u003eSIMATIC HMI IPC677C\u003c\/strong\u003e, engineered to handle simultaneous human-machine interface (HMI) visualization and demanding real-time machine control tasks. This heavy-duty system features a broad \u003cstrong\u003e15-inch display\u003c\/strong\u003e paired with an integrated rugged tactile keypad layout supporting a native resolution of \u003cstrong\u003e1024 x 768 pixels\u003c\/strong\u003e. It is equipped with dual integrated \u003cstrong\u003e10\/100\/1000 Mbit\/s Gigabit Ethernet ports\u003c\/strong\u003e for independent control and corporate IT routing, four rear-mounted USB 2.0 ports, and a front-side USB port for quick maintenance access. Plant-floor reliability is optimized via an onboard hardware \u003cstrong\u003eRAID controller\u003c\/strong\u003e for data redundancy alongside persistent internal system watchdog, temperature, and fan status monitoring circuits. Operating on an industrial wide-range \u003cstrong\u003e110\/230 V AC power supply\u003c\/strong\u003e designed to strict NAMUR specifications, this obsolete hardware serves as a critical drop-in node to maintain continuous uptime across legacy production lines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 16px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKeypad-Driven Display Node:\u003c\/strong\u003e Ruggedized 15-inch display with a built-in industrial keypad panel interface designed for reliable operator inputs in harsh environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Channel Gigabit Trunking:\u003c\/strong\u003e Equipped with two independent 10\/100\/1000 Mbit\/s Ethernet interfaces to ensure clean operational network segmentation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault-Tolerant Storage System:\u003c\/strong\u003e Integrated hardware RAID controller enables real-time storage mirroring to minimize mechanical failure risks and process downtime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProactive Health Diagnostics:\u003c\/strong\u003e Onboard watchdog micro-circuits alongside direct fan and temperature monitoring utilities maintain system integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 16px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupervisory Control \u0026amp; SCADA Nodes:\u003c\/strong\u003e Central machine-level visualization terminal designed for managing distributed plant sectors and assembly structures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturing Execution Systems (MES):\u003c\/strong\u003e High-reliability computing node for localized material tracking, recipe management, and ERP data interfacing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLegacy System Architecture Support:\u003c\/strong\u003e Drop-in direct-replacement platform to ensure continuous execution of custom control systems running on vintage IPC677C setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 16px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px 12px; color: #1a365d;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px 12px; color: #1a365d;\"\u003eVerified Technical Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e6AV7423-2AA01-0LS0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eSIMATIC Panel PC IPC677C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eIndustrial Panel PC HMI Workstation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDisplay Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e15-inch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eOperator Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eIntegrated Tactile Keypad Panel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eNative Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eMains Power Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e110\/230 V AC Power Module (NAMUR Compliant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eNetwork Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e2 x 10\/100\/1000 Mbit\/s Gigabit Ethernet Ports\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e4 x USB 2.0 (Rear Face), 1 x USB Interface (Front Face)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eSerial Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e1 x COM1 (RS-232)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eData Redundancy\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eOnboard Hardware RAID Controller Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eDiagnostic Monitoring\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eWatchdog, Internal Temperature Control, Fan Status Control\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eProduct Phase Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eObsolete \/ Legacy Production Node\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003eNet Shipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px;\"\u003e55.0 x 45.0 x 25.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px 16px; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 4px;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate, shut down, and verify all upstream electrical feeder channels prior to mechanical mounting. Ensure total compliance with proper Lockout\/Tagout (LOTO) procedures. Cabinet wiring and hardware provisioning must be completed exclusively by certified industrial engineering personnel.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 16px; color: #2d3748;\"\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eEnclosure Verification:\u003c\/strong\u003e Ensure the target electrical cabinet is fully de-energized, checking for the absolute absence of residual voltage using a properly calibrated testing tool.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eCutout Dimensions Audit:\u003c\/strong\u003e Cross-check the panel layout cutout geometry against the exact installation footprint of the IPC677C chassis. Confirm the surface area is clean, flat, and structurally reinforced.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eWorkstation Alignment \u0026amp; Clamping:\u003c\/strong\u003e Seat the workstation into the prepared cutout from the front. Secure the frame tightly from the rear side using all supplied mounting brackets, applying uniform torque to create a tight front gasket seal.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eProtective Earth Grounding:\u003c\/strong\u003e Run a dedicated, low-impedance copper protective earth (PE) grounding wire directly to the chassis ground stud. This step is mandatory to minimize electromagnetic interference (EMI) and establish safety boundaries.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eMains Power Termination:\u003c\/strong\u003e Wire the main 110\/230 V AC supply cables (Line, Neutral, and Earth) straight into the designated power distribution block terminals, verifying that feed voltages fit the product nameplate ratings.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e6\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eTrunk Interface Connections:\u003c\/strong\u003e Attach all structural communication links, Gigabit Ethernet connections, serial lines, and USB cables. Utilize proper cord tracking mechanisms to prevent accidental strain or mechanical disconnects.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e7\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eEnclosure Boot Evaluation:\u003c\/strong\u003e Secure the enclosure door assemblies, restore branch circuit power, and monitor the device initialization phase to verify complete boot performance and network link state connectivity.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715765989739,"sku":"6AV7423-2AA01-0LS0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7423-2aa01-0ls0-31lenim45m4_de65ec37-01e8-4b06-93a1-60084e1116a0.jpg?v=1767070600","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7423-2aa01-0ls0-simatic-hmi-ipc677c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}