{"product_id":"siemens-6av7611-0af22-0bj0-simatic-panel-pc-670","title":"Siemens 6AV7611-0AF22-0BJ0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe 6AV7611-0AF22-0BJ0 is a SIMATIC Panel PC 670 from Siemens, designed for integrated control and visualization tasks in industrial environments. This unit is equipped with a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e and is powered by a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e with \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e. For storage and software, it includes a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e, a CD-ROM drive, and comes pre-installed with the \u003cstrong\u003eWindows NT 4.0\u003c\/strong\u003e operating system. The device is configured for a wide input voltage range and includes a U.S. mains cable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e10-inch TFT color display for HMI applications.\u003c\/li\u003e\n  \u003cli\u003ePentium III 500 MHz processor.\u003c\/li\u003e\n  \u003cli\u003e128 MB of installed RAM.\u003c\/li\u003e\n  \u003cli\u003eIncludes a 40 GB hard drive and a CD-ROM drive.\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Windows NT 4.0 (English).\u003c\/li\u003e\n  \u003cli\u003eSupports a 115-230V AC power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine-level data acquisition and visualization.\u003c\/li\u003e\n  \u003cli\u003eProcess control and monitoring in manufacturing facilities.\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes.\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eCategory\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eGeneral\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eHardware\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e10-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePentium III 500 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40 GB Hard Drive, CD-ROM Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eSoftware\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWindows NT 4.0 (English)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eElectrical\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e115-230 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eIncluded Cable\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eU.S. Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eLogistical\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e35 x 30 x 15 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 24px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/strong\u003e\n  \u003cp style=\"margin-top: 8px; margin-bottom: 0;\"\u003eDisconnect all power sources before installation or maintenance. This device is intended for use in a grounded, stationary control cabinet accessible only to qualified personnel. Failure to follow proper Lockout\/Tagout (LOTO) procedures can result in serious injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 15px;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cstrong\u003ePrepare Enclosure:\u003c\/strong\u003e Ensure the mounting location is clean, dry, and free from excessive vibration. Verify that the panel cutout dimensions match the unit's specifications for a secure fit.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 15px;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the prepared cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the panel surface.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 15px;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect the 115-230V AC mains cable to a properly rated and protected power source. Ensure a solid protective earth (PE) ground connection is established at the designated terminal.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 15px;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required communication, network (Ethernet), and peripheral (keyboard, mouse) cables to their respective ports. Ensure proper cable strain relief and routing within the cabinet.\n  \u003c\/li\u003e\n  \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 15px;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n    \u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections are secure and the enclosure is closed, re-apply power to the cabinet. Power on the Panel PC and proceed with system configuration and software commissioning.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716415353195,"sku":"6AV7611-0AF22-0BJ0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0af22-0bj0-vta4ilnx3ih_3d50a072-ca71-4ce3-84dd-309a39fb8e9e.jpg?v=1767082500","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7611-0af22-0bj0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}