{"product_id":"siemens-6av7615-0ae20-0bh0-simatic-panel-pc-670","title":"Siemens 6AV7615-0AE20-0BH0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7615-0AE20-0BH0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit features a \u003cstrong\u003e15-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003e300 MHz Celeron CPU\u003c\/strong\u003e, \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e. It is supplied with a pre-installed German version of the Windows NT 4.0 operating system and includes a U.S. mains cable for operation on \u003cstrong\u003e115-230 V\u003c\/strong\u003e power sources. Please note that this product line is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e15-inch TFT color display for process visualization.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003ePowered by a 300 MHz Celeron processor.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003eEquipped with 128 MB RAM and a 40 GB hard drive.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003ePre-loaded with Windows NT 4.0 operating system (German language).\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003eFlexible input voltage range of 115-230 V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003eLegacy HMI systems requiring direct hardware replacement.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003eMachine control and process visualization panels.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003eData acquisition and monitoring stations in manufacturing environments.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0.5em; position: relative; padding-left: 20px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003eMaintaining operational continuity for systems built around the SIMATIC PC 670 platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 300px;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7615-0AE20-0BH0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Family\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePC 670\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15-inch TFT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor (CPU)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e128 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows NT 4.0 (German)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eInput Voltage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e115-230 V AC (via included U.S. mains cable)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e55 cm x 45 cm x 20 cm (Estimated)\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 15px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 1em;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout\/Tagout (LOTO) procedures before installation can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"margin-bottom: 1em; position: relative; padding-left: 40px; line-height: 1.6;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n        \u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before beginning installation, completely disconnect all power sources from the control panel or machine. Verify the absence of voltage using a properly rated test instrument. Apply appropriate LOTO devices.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 1em; position: relative; padding-left: 40px; line-height: 1.6;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n        \u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the panel cutout dimensions match the PC 670's requirements for a secure fit. The mounting surface must be flat, clean, and capable of supporting the unit's weight. Verify adequate clearance for ventilation and cable routing.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 1em; position: relative; padding-left: 40px; line-height: 1.6;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n        \u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly and sequentially to ensure a uniform seal against the panel gasket. Do not overtighten.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 1em; position: relative; padding-left: 40px; line-height: 1.6;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n        \u003cstrong\u003eConnect Power and Ground:\u003c\/strong\u003e Connect the AC mains cable to a stable, correctly rated power source. Ensure a low-impedance connection to the protective earth (PE) ground terminal on the chassis to minimize electrical noise and ensure safety.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 1em; position: relative; padding-left: 40px; line-height: 1.6;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n        \u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required communication cables, keyboards, mice, and other I\/O devices. Ensure all connectors are fully seated and secured.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 1em; position: relative; padding-left: 40px; line-height: 1.6;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e6\u003c\/span\u003e\n        \u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections, remove LOTO devices and re-apply power to the system. Observe the Panel PC during its boot sequence to confirm normal operation.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716307120491,"sku":"6AV7615-0AE20-0BH0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7615-0ae20-0bh0-lm3qqisgl1b_b228473e-8926-470c-8e19-a60755ec669f.jpg?v=1767080453","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7615-0ae20-0bh0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}