{"product_id":"siemens-6av7725-2bc10-0ad0-simatic-panel-pc-670","title":"Siemens 6AV7725-2BC10-0AD0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a SIMATIC Panel PC 670 from Siemens, model \u003cstrong\u003e6AV7725-2BC10-0AD0\u003c\/strong\u003e, designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit is equipped with a \u003cstrong\u003e15.1-inch color TFT display\u003c\/strong\u003e, a \u003cstrong\u003ePentium III 1.26 GHz processor\u003c\/strong\u003e, and \u003cstrong\u003e256 MB of SDRAM\u003c\/strong\u003e. It includes a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e for data storage and a DVD-ROM drive. The system is powered by a 115-230V AC supply and comes pre-installed with the Windows 2000 multi-language operating system.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003e15.1-inch Color TFT Display\u003c\/li\u003e\n    \u003cli\u003eIntel Pentium III 1.26 GHz Processor\u003c\/li\u003e\n    \u003cli\u003e256 MB SDRAM-133 Memory (1 x 256 MB module)\u003c\/li\u003e\n    \u003cli\u003e40 GB EIDE Hard Disk Drive (HDD)\u003c\/li\u003e\n    \u003cli\u003eIntegrated DVD-ROM Optical Drive\u003c\/li\u003e\n    \u003cli\u003e115-230V AC Power Supply Unit\u003c\/li\u003e\n    \u003cli\u003ePre-installed Windows 2000 Operating System (Multi-language)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) for process visualization\u003c\/li\u003e\n    \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) client nodes\u003c\/li\u003e\n    \u003cli\u003eMachine-level data logging and analysis\u003c\/li\u003e\n    \u003cli\u003eIndustrial control panel integration\u003c\/li\u003e\n    \u003cli\u003eFactory automation and assembly line control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e6AV7725-2BC10-0AD0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIndustrial Panel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e15.1-inch Color TFT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePentium III 1.26 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eMemory\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e256 MB SDRAM-133\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e40 GB HDD EIDE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDVD-ROM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eWindows 2000 (Multi-language)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e115-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIncluded Cable\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e5D992\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize the control panel and follow Lockout\/Tagout (LOTO) procedures before installation can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003ePrepare Enclosure:\u003c\/strong\u003e Ensure the panel cutout dimensions are correct for the PC 670 chassis. Verify that the mounting surface is flat, clean, and capable of supporting the unit's weight (12.00 kg).\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Carefully insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect a dedicated protective earth (PE) conductor to the designated grounding terminal on the PC chassis. This is critical for electrical safety and noise immunity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e With the main power still off, connect the AC mains cable to the unit's power input. Ensure the source voltage (115-230V AC) matches the supply configuration. Route the power cable away from sensitive data lines.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required communication, USB, and video cables. Ensure all connectors are fully seated and secured. Maintain proper bend radii for all cabling to prevent damage.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e Verify all connections are secure and that there is adequate ventilation around the unit's heat sink. Remove all tools from the enclosure, close the panel door, and re-apply power to the cabinet.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715866980715,"sku":"6AV7725-2BC10-0AD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7725-2bc10-0ad0-hes23ndhvey_06a6c994-e8b1-4f54-8ca7-6270087f4df9.jpg?v=1767073248","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7725-2bc10-0ad0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}