{"product_id":"siemens-6av7812-0ac20-2ab0-simatic-panel-pc-877","title":"Siemens 6AV7812-0AC20-2AB0 SIMATIC Panel PC 877","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7812-0AC20-2AB0 is a SIMATIC Panel PC 877 designed for industrial human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e1024x768 pixels\u003c\/strong\u003e and is powered by a \u003cstrong\u003e2.2 GHz Pentium 4 Mobile processor\u003c\/strong\u003e. It is equipped with \u003cstrong\u003e1GB of DDR266 SDRAM\u003c\/strong\u003e, a \u003cstrong\u003e40 GByte EIDE hard drive\u003c\/strong\u003e, and a combination CD-R\/RW\/DVD optical drive. The panel includes a front-side USB interface for convenient peripheral access and operates on a standard \u003cstrong\u003e24V DC\u003c\/strong\u003e power supply. This model comes pre-installed with the Windows 2000 Professional Multi-User Interface (MUI) operating system.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003e15-inch color touch screen display\u003c\/li\u003e\n    \u003cli\u003e1024 x 768 pixel screen resolution\u003c\/li\u003e\n    \u003cli\u003ePentium 4 Mobile 2.2 GHz processor\u003c\/li\u003e\n    \u003cli\u003e1GB DDR266 SDRAM (configured as 2x512MB)\u003c\/li\u003e\n    \u003cli\u003e40 GByte EIDE 3.5-inch hard disk drive\u003c\/li\u003e\n    \u003cli\u003eIntegrated CD-R\/RW\/DVD combo optical drive\u003c\/li\u003e\n    \u003cli\u003eConvenient front-side USB interface\u003c\/li\u003e\n    \u003cli\u003eStandard 24V DC power input\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eProcess visualization and SCADA systems\u003c\/li\u003e\n    \u003cli\u003eMachine control and operator interface panels\u003c\/li\u003e\n    \u003cli\u003eData acquisition and logging stations\u003c\/li\u003e\n    \u003cli\u003eIndustrial automation control rooms\u003c\/li\u003e\n    \u003cli\u003eManufacturing execution systems (MES)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePanel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eDisplay Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e15-inch Touch Screen\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eDisplay Resolution\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePentium 4 Mobile 2.2 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProcessor Cache\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e512KB SLC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eFront Side Bus (FSB)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e400 MHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e1GB DDR266 SDRAM (2x512MB)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e40 GByte EIDE 3.5-inch HDD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eCD-R\/RW\/DVD (Combo)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eInterfaces\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eFront Side USB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e24V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eWindows 2000 Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e67.0 x 83.0 x 11.5 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e17.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or servicing to prevent electric shock or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Verify that the panel cutout dimensions match the unit's specifications. Ensure adequate clearance for ventilation around the rear of the unit to prevent overheating.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eMount the Panel PC:\u003c\/strong\u003e Insert the Panel PC into the prepared cutout from the front of the enclosure. Secure it evenly using all provided mounting clamps and hardware, tightening to the manufacturer's recommended torque specification to ensure a proper seal.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect the chassis grounding terminal to the control cabinet's protective earth busbar using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect a stable, regulated 24V DC power source to the designated power input terminals. Verify correct polarity (+\/-) before energizing the circuit. Use appropriate wire gauges for the current draw.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect necessary peripherals such as keyboards, mice, and network cables to the appropriate ports. Utilize the front-side USB port for temporary devices like flash drives. Power on the unit and verify system startup and operation.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715878613355,"sku":"6AV7812-0AC20-2AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7812-0ac20-2ab0-ck0kwgpnbgm_670ae4b8-8ee2-4d11-9ba0-9c017569895e.jpg?v=1767073556","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7812-0ac20-2ab0-simatic-panel-pc-877","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}