{"product_id":"siemens-6av7812-1bb11-2ab0-simatic-panel-pc-877-touch","title":"Siemens 6AV7812-1BB11-2AB0 SIMATIC Panel PC 877 Touch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6AV7812-1BB11-2AB0\u003c\/strong\u003e is a SIMATIC Panel PC 877, designed for industrial human-machine interface (HMI) and control applications. This Panel PC features a 15-inch touch display with a resolution of 1024x768 pixels. It is configured without a front-side USB interface and operates on an AC110-230V power supply, supplied with a power cable suitable for Europe. Internally, the unit is equipped with a Pentium 4 processor running at 2.8 GHz with a 533 MHz Front Side Bus (FSB), 512KB SLC cache, and 512MB of DDR266 SDRAM (1x512MB). Storage is provided by an 80 GBYTE EIDE 3.5-inch Hard Disk Drive (HDD) and an integrated CD-R\/RW\/DVD (COMBO) optical drive. The system comes pre-installed with Windows 2000 Professional Multi-User Interface (MUI), supporting English, German, French, Italian, Spanish, Japanese, Chinese, and Korean languages, making it suitable for diverse industrial environments requiring robust computing and visualization capabilities.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e15-inch Touch Display\u003c\/li\u003e\n\u003cli\u003e1024x768 Pixel Resolution\u003c\/li\u003e\n\u003cli\u003ePentium 4 2.8 GHz Processor\u003c\/li\u003e\n\u003cli\u003e533 MHz FSB and 512KB SLC Cache\u003c\/li\u003e\n\u003cli\u003e512MB DDR266 SDRAM (1x512MB)\u003c\/li\u003e\n\u003cli\u003e80 GBYTE EIDE 3.5-inch HDD\u003c\/li\u003e\n\u003cli\u003eIntegrated CD-R\/RW\/DVD (COMBO) Drive\u003c\/li\u003e\n\u003cli\u003eAC110-230V Power Input\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows 2000 Professional MUI\u003c\/li\u003e\n\u003cli\u003eNo Front-Side USB Interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Human-Machine Interface (HMI)\u003c\/li\u003e\n\u003cli\u003eMachine Control and Visualization Systems\u003c\/li\u003e\n\u003cli\u003eProcess Monitoring and Data Acquisition\u003c\/li\u003e\n\u003cli\u003eFactory Automation and Production Line Management\u003c\/li\u003e\n\u003cli\u003eOperator Control Stations in Manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC panels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024x768\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTouch Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFront USB Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAC110-230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEurope\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePentium 4 2.8 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFSB Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e533 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSLC Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e512KB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e512MB DDR266 SDRAM (1x512MB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e80 GBYTE HDD EIDE 3.5\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCD-R\/RW\/DVD (COMBO)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 2000 Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower De-energization:\u003c\/strong\u003e Before commencing installation, ensure all power to the installation area and the Panel PC is de-energized and locked out according to safety procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Panel PC in a suitable industrial enclosure or panel cutout, ensuring adequate space for ventilation and cable routing. Refer to the specific mounting instructions for the SIMATIC Panel PC 877 series.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the AC110-230V power supply to the designated power input terminals on the Panel PC using the provided Europe power cable. Verify correct voltage and polarity before applying power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all power, data, and peripheral cables to prevent strain, interference, and damage. Use appropriate cable glands and conduits where necessary.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure that the installation location provides sufficient airflow to prevent overheating, especially given the internal components like the processor and hard drive.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect any required industrial peripherals, such as keyboards, mice, or other devices, to the available interfaces on the Panel PC. Note that this specific model does not include a front-side USB interface.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e After all connections are verified, re-energize the system and power on the Panel PC. Monitor the startup sequence to confirm proper operation of the display and operating system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715880874347,"sku":"6AV7812-1BB11-2AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7812-1bb11-2ab0-h4d1jyzmuc3_f45295a9-2c5a-48ea-9b14-d6a238467626.jpg?v=1767073642","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7812-1bb11-2ab0-simatic-panel-pc-877-touch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}