{"product_id":"siemens-6av7820-0aa10-1ab0-simatic-panel-pc-577","title":"Siemens 6AV7820-0AA10-1AB0 SIMATIC Panel PC 577","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7820-0AA10-1AB0 is a SIMATIC Panel PC 577, an industrial-grade computer designed for human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e12-inch touch display\u003c\/strong\u003e, is powered by a \u003cstrong\u003eCeleron 2.0 GHz processor\u003c\/strong\u003e, and is equipped with \u003cstrong\u003e512 MB of DDR400 SDRAM\u003c\/strong\u003e. It includes a DVD-ROM drive and comes pre-installed with a multi-language version of Windows 2000 SP4 Professional. This model is suitable for legacy system maintenance and replacements where specific hardware and software configurations are required.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003e12-inch integrated touch screen display for operator control.\u003c\/li\u003e\n\u003cli\u003eCeleron processor operating at 2.0 GHz.\u003c\/li\u003e\n\u003cli\u003e512 MB DDR400 SDRAM for application processing.\u003c\/li\u003e\n\u003cli\u003eIntegrated DVD-ROM optical drive.\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows 2000 SP4 Professional (MUI).\u003c\/li\u003e\n\u003cli\u003eDesigned for panel mounting in industrial enclosures.\u003c\/li\u003e\n\u003cli\u003eNote: This product is classified as obsolete by the manufacturer, making it a critical spare for existing systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eProcess visualization and control\u003c\/li\u003e\n\u003cli\u003eMachine-level data acquisition and logging\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n\u003cli\u003eFactory automation and assembly line monitoring\u003c\/li\u003e\n\u003cli\u003eReplacement for identical legacy HMI systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7820-0AA10-1AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePC 577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12-inch Touch Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCeleron 2.0 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e512 MB DDR400 SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eOptical Drive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDVD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eOperating System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows 2000 SP4 Professional MUI (Multi-User Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eProduct Lifecycle Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e64.00 x 64.00 x 42.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eECCN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003cstrong\u003ePackage Dimensions (Calculated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e64.00 x 64.00 x 42.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 15px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 15px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present within industrial control panels. All installation, maintenance, and troubleshooting activities must be performed by qualified personnel who are knowledgeable about electrical safety standards and procedures. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely de-energize the control cabinet. Use a calibrated multimeter to verify zero energy state. Apply Lockout\/Tagout (LOTO) procedures to prevent accidental re-energization.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Ensure the panel cutout dimensions match the PC 577's requirements. Secure the unit into the panel using all provided mounting clamps, tightening them evenly to create a proper seal and ensure mechanical stability.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis ground terminal of the Panel PC to the cabinet's protective earth bus bar using a low-impedance conductor. This is critical for both safety and noise immunity.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePower and I\/O Wiring:\u003c\/strong\u003e Connect the DC power supply, communication cables (e.g., Ethernet, PROFIBUS), and any other peripheral I\/O. Route signal and communication cables separately from high-voltage power lines to minimize electromagnetic interference.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections, remove LOTO devices and re-energize the cabinet. Power on the Panel PC and confirm that the operating system boots correctly and all connected devices are recognized.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715847450987,"sku":"6AV7820-0AA10-1AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7820-0aa10-1ab0-yra1wqk3hkv_214bb12e-c8fa-4825-ab33-b190faa76e2b.jpg?v=1767072517","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7820-0aa10-1ab0-simatic-panel-pc-577","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}