{"product_id":"siemens-6av7872-0ea20-1aa0-simatic-panel-pc-677b","title":"Siemens 6AV7872-0EA20-1AA0 SIMATIC Panel PC 677B","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a SIMATIC Panel PC 677B from Siemens, model 6AV7872-0EA20-1AA0, designed for industrial human-machine interface (HMI) and control applications. It features a \u003cstrong\u003e15-inch touchscreen\u003c\/strong\u003e display with a \u003cstrong\u003e1024 x 768 resolution\u003c\/strong\u003e. The unit is powered by an Intel \u003cstrong\u003eCeleron M 440 processor at 1.86 GHz\u003c\/strong\u003e and is equipped with \u003cstrong\u003e1 GB of DDR2 RAM\u003c\/strong\u003e. Connectivity options include dual \u003cstrong\u003e10\/100\/1000 Mbit\/s Ethernet ports\u003c\/strong\u003e, four rear USB 2.0 ports, a front-side USB interface, and a serial COM1 port. This configuration includes a \u003cstrong\u003e110\/230V AC power supply\u003c\/strong\u003e with a power cable for Switzerland and provides two PCI slots for expansion.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e15-inch touchscreen display with 1024 x 768 pixel resolution\u003c\/li\u003e\n\u003cli\u003eIntegrated Intel Celeron M 440 processor (1.86 GHz, 1MB SLC)\u003c\/li\u003e\n\u003cli\u003e1 GB DDR2 RAM for application processing\u003c\/li\u003e\n\u003cli\u003eDual Gigabit Ethernet ports (2x 10\/100\/1000 Mbit\/s)\u003c\/li\u003e\n\u003cli\u003eFour rear USB 2.0 ports and one front-side USB interface for peripheral access\u003c\/li\u003e\n\u003cli\u003eOne serial (COM1) interface for legacy device communication\u003c\/li\u003e\n\u003cli\u003eTwo PCI slots for hardware expansion\u003c\/li\u003e\n\u003cli\u003eOperates on a 110\/230V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eProcess visualization and control systems\u003c\/li\u003e\n\u003cli\u003eMachine data acquisition and monitoring\u003c\/li\u003e\n\u003cli\u003eFactory automation operator interfaces\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n\u003cli\u003eIndustrial computing platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePC677B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e15-inch Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIntel Celeron M 440 \/ 1.86 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor Cache\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 MB SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 GB DDR2 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUSB Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4 x USB 2.0 (rear), 1 x USB (front)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSerial Port\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 x COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x PCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e110\/230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded Power Cable\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePLM Product Phase\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e84714100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e5D992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e17.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e67.0 x 83.0 x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 20px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to follow proper safety procedures, including Lockout\/Tagout (LOTO), can result in severe injury or death. Always wear appropriate Personal Protective Equipment (PPE).\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely de-energize the control cabinet or mounting location. Verify the absence of voltage using a calibrated multimeter. Apply LOTO procedures as required by site safety protocols.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Prepare the panel cutout according to the manufacturer's dimensional drawings. Secure the Panel PC into the cutout using all provided mounting clamps, tightening them evenly to ensure a proper seal and prevent chassis distortion.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProtective Earth Connection:\u003c\/strong\u003e Connect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the Panel PC chassis. This is critical for both operator safety and noise immunity. Use the appropriate wire gauge and a secure, vibration-resistant termination.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect the 110\/230V AC power supply cable to the unit's power input connector. Ensure the source voltage matches the unit's rating. Route the power cable away from sensitive signal or communication wiring to minimize electrical noise.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Interfaces:\u003c\/strong\u003e Connect Ethernet, USB, and serial cables as required by the application. Use shielded cables for all data communication where possible. Ensure all connectors are fully seated and secured.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e After all connections are made, remove LOTO devices and re-energize the cabinet. Power on the Panel PC and verify correct boot-up and system operation. Proceed with software configuration and commissioning.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715869536619,"sku":"6AV7872-0EA20-1AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7872-0ea20-1aa0-deqbmi2y4tg_005e72a4-8173-4d96-8ec9-0c0b2b856050.jpg?v=1767073324","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7872-0ea20-1aa0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}