{"product_id":"siemens-6av7873-0ca20-1aa0-simatic-panel-pc-677b","title":"Siemens 6AV7873-0CA20-1AA0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6AV7873-0CA20-1AA0\u003c\/strong\u003e is a SIMATIC Panel PC 677B, designed for industrial human-machine interface (HMI) and control applications. This robust panel PC integrates a 15-inch display with a 1024x768 resolution, featuring a key interface for operator interaction. It is equipped with a Celeron M440 processor running at 1.86 GHz, 1 GB of DDR2 RAM, and a 160 GB SATA hard disk drive. Connectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports, a front-side USB interface, and one serial (COM1) port. For industrial communication, it supports PROFIBUS\/MP. The unit also includes a DVD+-R+-RW optical drive, 2 MB of buffered SRAM, and is supplied without an operating system, allowing for flexible software deployment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 15-inch display with 1024x768 resolution and key interface\u003c\/li\u003e\n\u003cli\u003eCeleron M440\/1.86 GHz processor with 1 MB SLC cache\u003c\/li\u003e\n\u003cli\u003e1 GB DDR2 RAM\u003c\/li\u003e\n\u003cli\u003e160 GB SATA 3.5\" Hard Disk Drive\u003c\/li\u003e\n\u003cli\u003eDVD+-R+-RW optical drive\u003c\/li\u003e\n\u003cli\u003e2x 10\/100\/1000 Mbit\/s Ethernet ports\u003c\/li\u003e\n\u003cli\u003e4x USB V2.0 ports and 1x front-side USB interface\u003c\/li\u003e\n\u003cli\u003e1x Serial (COM1) port\u003c\/li\u003e\n\u003cli\u003ePROFIBUS\/MP communication interface\u003c\/li\u003e\n\u003cli\u003e2 MB Buffered SRAM\u003c\/li\u003e\n\u003cli\u003e110\/230 V AC power supply unit with NAMUR functionality\u003c\/li\u003e\n\u003cli\u003e2x PCI expansion slots\u003c\/li\u003e\n\u003cli\u003eSupplied without an operating system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe SIMATIC Panel PC 677B is suitable for a wide range of industrial applications requiring a compact and robust computing platform. Typical uses include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMachine control and visualization\u003c\/li\u003e\n\u003cli\u003eProcess monitoring and data acquisition\u003c\/li\u003e\n\u003cli\u003eOperator interface for complex systems\u003c\/li\u003e\n\u003cli\u003eIndustrial data processing and logging\u003c\/li\u003e\n\u003cli\u003eEmbedded control systems in manufacturing and automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC Panel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024x768\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCeleron M440\/1.86 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 MB SLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 GB DDR2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Disk Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e160 GB SATA 3.5\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0, 1x Front-side USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x (COM1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFieldbus Communication\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230 V AC (with NAMUR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x PCI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized before beginning any work. Follow all local safety regulations and lockout\/tagout procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Panel PC into a suitable control cabinet or panel cutout. Ensure adequate space for ventilation and cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 110\/230 V AC power supply to the designated terminals. Verify correct voltage and polarity before applying power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the chassis of the Panel PC to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Connections:\u003c\/strong\u003e Connect industrial Ethernet cables to the 10\/100\/1000 Mbit\/s Ethernet ports for network communication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUSB and Serial Connections:\u003c\/strong\u003e Connect peripheral devices (e.g., keyboard, mouse, barcode scanner) to the USB ports and any serial devices to the COM1 port as required.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP Connection:\u003c\/strong\u003e If utilizing PROFIBUS\/MP, connect the appropriate bus cable to the designated interface, ensuring correct termination.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all cables to prevent strain, interference, and damage. Use cable ties and conduits where necessary.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInitial Power-Up:\u003c\/strong\u003e After all connections are verified, apply power to the Panel PC. Monitor for proper boot-up and system status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715896832363,"sku":"6AV7873-0CA20-1AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7873-0ca20-1aa0-xgylvsr5zqs_15d290cb-1671-4858-8026-e0af25ffac29.jpg?v=1767074233","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7873-0ca20-1aa0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}