{"product_id":"siemens-6av7893-0be30-1ab0-simatic-hmi-ipc677c-panel-pc","title":"Siemens 6AV7893-0BE30-1AB0 SIMATIC HMI IPC677C Panel PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6AV7893-0BE30-1AB0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC HMI IPC677C Panel PC\u003c\/strong\u003e designed for robust and reliable operation in demanding industrial environments. This unit integrates a 15-inch display with a 1024 x 768 resolution and an accessible front-side USB interface. It is equipped with an \u003cstrong\u003eIntel Core i3-330E\u003c\/strong\u003e processor (2 cores, 4 threads, 2.13 GHz), 4 GB DDR3 memory, and a 250 GB SATA hard disk, along with a DVD+-R+-RW drive for data storage and software installation. The \u003cstrong\u003e6AV7893-0BE30-1AB0\u003c\/strong\u003e features extensive connectivity, including two Gigabit Ethernet ports, four USB 2.0 ports, one serial COM1 port, and an onboard CP 5611-A2-compatible interface for PROFIBUS\/MPI. Enhanced reliability features include a built-in RAID controller, 2 MB buffered SRAM, and watchdog, temperature, and fan monitoring. It comes pre-installed with Windows XP Professional SP3 MUI, supporting multiple languages (German, English, French, Spanish, Italian), and is powered by a 110\/230 V AC supply unit with NAMUR standard, complete with a European power cable.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated 15-inch display with 1024 x 768 resolution\u003c\/li\u003e\n  \u003cli\u003eIntel Core i3-330E processor (2 cores, 4 threads, 2.13 GHz, HT, VT, 3 MB cache)\u003c\/li\u003e\n  \u003cli\u003e4 GB DDR3 1066 DIMM RAM\u003c\/li\u003e\n  \u003cli\u003e250 GB SATA Hard Disk Drive and DVD+-R+-RW optical drive\u003c\/li\u003e\n  \u003cli\u003eDual Gigabit Ethernet ports (2x 10\/100\/1000 Mbit\/s)\u003c\/li\u003e\n  \u003cli\u003eFour USB V2.0 ports (including front-side USB-Schnittstelle)\u003c\/li\u003e\n  \u003cli\u003eOne serial (COM1) port\u003c\/li\u003e\n  \u003cli\u003ePROFIBUS\/MPI (CP 5611-A2-compatible) interface\u003c\/li\u003e\n  \u003cli\u003eOnboard RAID controller and 2 MB buffered SRAM\u003c\/li\u003e\n  \u003cli\u003eWatchdog, temperature, and fan monitoring functions\u003c\/li\u003e\n  \u003cli\u003e110\/230 V AC power supply unit with NAMUR standard\u003c\/li\u003e\n  \u003cli\u003ePre-installed Windows XP Professional SP3 MUI (de, en, fr, es, it)\u003c\/li\u003e\n  \u003cli\u003eTwo free PCI expansion slots\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens SIMATIC HMI IPC677C Panel PC is suitable for a wide range of industrial applications requiring integrated control, monitoring, and visualization capabilities. Typical deployments include:\n\u003cul\u003e\n  \u003cli\u003eMachine control and operation within manufacturing environments\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and data acquisition in industrial plants\u003c\/li\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) applications for production lines\u003c\/li\u003e\n  \u003cli\u003eIndustrial data logging and archiving solutions\u003c\/li\u003e\n  \u003cli\u003eFront-end computing for Distributed Control Systems (DCS) and Supervisory Control and Data Acquisition (SCADA) systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIPC677C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC panels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024 x 768\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore I3-330E (2C\/4T, 2.13 GHz, HT, VT, 3 MB cache)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 GB DDR3 1066 DIMM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Disk Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e250 GB SATA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x (COM1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MPI Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCP 5611-A2-compatible\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x PCI free\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Prof. SP3 MUI (de, en, fr, es, it)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230 V AC with NAMUR\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.45 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eQuantity \/ Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s ports\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0 ports (including a front-side interface)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x COM1 port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MPI\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOnboard CP 5611-A2-compatible interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230 V AC input with NAMUR standard\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and associated equipment is completely de-energized and locked out before beginning any work.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Panel PC into a prepared panel cutout, ensuring proper sealing to maintain the specified IP rating of the front panel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the provided European power cable to the 110\/230 V AC power supply unit, adhering to local electrical codes and safety standards. Verify correct voltage and grounding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a robust protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterface Cabling:\u003c\/strong\u003e Connect Ethernet, USB, and serial communication cables to their respective ports. Ensure proper cable routing to avoid strain and interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MPI Connection:\u003c\/strong\u003e If utilizing the PROFIBUS\/MPI interface, connect the bus cable according to the PROFIBUS standard, ensuring correct termination and shielding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the installation environment is within the specified operating temperature and humidity ranges to prevent damage and ensure reliable operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower On:\u003c\/strong\u003e After all connections are verified, re-energize the system and observe for proper startup and functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715845386603,"sku":"6AV7893-0BE30-1AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7893-0be30-1ab0-if5hwyi5422_bbf3f23a-2564-4faa-8d51-c0eb3cf67f17.jpg?v=1767072447","url":"https:\/\/www.plcprotech.com\/products\/siemens-6av7893-0be30-1ab0-simatic-hmi-ipc677c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}