{"product_id":"siemens-6es5458-7lb11-simatic-s5-relay-output-module","title":"Siemens 6ES5458-7LB11 SIMATIC S5 Relay Output Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6ES5458-7LB11 is a relay output module designed for the SIMATIC S5 PLC system. This module provides \u003cstrong\u003e16 SPDT relay channels\u003c\/strong\u003e for switching a variety of AC and DC loads in industrial control applications. It is engineered for reliable operation in demanding environments, offering robust performance for controlling motors, valves, and other field devices. The panel-mount design facilitates straightforward integration into standard control cabinets.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eProvides 16 independent relay output channels\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFeatures Single-Pole Double-Throw (SPDT) relay contacts\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eCompatible with both AC and DC load switching\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eDesigned for use within the Siemens SIMATIC S5 automation platform\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003ePanel-mount form factor for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eMotor and drive control\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eHVAC system management\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eCritical process control applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eEnergy management systems\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eGeneral manufacturing automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eModel Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6ES5458-7LB11\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC S5\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eModule Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eRelay Output Module\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eNumber of Channels\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e16\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eContact Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSPDT (Single-Pole Double-Throw)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eActive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCondition\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eBrand New\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e0.7 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e33 x 5.1 x 20.3 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect and lock out all power sources to the PLC rack and associated equipment before installation or removal. Failure to de-energize the system can result in severe injury or death. All work must be performed by qualified personnel.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan style=\"color: #2d3748;\"\u003eVerify that the control panel is de-energized and locked out. Confirm zero voltage with a calibrated multimeter.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan style=\"color: #2d3748;\"\u003eIdentify the target slot in the SIMATIC S5 rack. Ensure the slot is compatible with the 6ES5458-7LB11 module type.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan style=\"color: #2d3748;\"\u003eAlign the module with the card guides in the rack and slide it firmly into place until the backplane connector is fully seated.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan style=\"color: #2d3748;\"\u003eSecure the module to the rack using its integrated fastening screws. Do not overtighten.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan style=\"color: #2d3748;\"\u003eConnect field wiring to the front connector terminals. Use appropriate wire gauges and ferrules. Ensure signal wiring is routed separately from high-voltage power cables to minimize noise.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        \u003cspan style=\"color: #2d3748;\"\u003eAfter all connections are verified, remove the lockout\/tagout devices and re-energize the system. Monitor module status indicators for correct operation.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695213212011,"sku":"6ES5458-7LB11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es5458-7lb11-relay-output-module-b1n4ngusw2v_b042886c-8fc6-45b6-826b-1107a69d7b0c.jpg?v=1766130889","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es5458-7lb11-simatic-s5-relay-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}