{"product_id":"siemens-6es7134-4jb50-0ab0-et-200s-analog-input-module","title":"Siemens 6ES7134-4JB50-0AB0 ET 200S Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6ES7134-4JB50-0AB0\u003c\/strong\u003e is a high-precision RTD (Resistance Temperature Detector) input module designed for the \u003cstrong\u003eET 200S\u003c\/strong\u003e distributed I\/O system. This compact module, featuring a 15mm width housing, provides 2 channels for resistance temperature detection. It offers 15-bit plus sign resolution for accurate temperature measurement and supports a variety of sensor types, including Pt100, Ni100 standard and climatic versions, as well as 150Ω, 300Ω, and 600Ω resistance ranges. The \u003cstrong\u003e6ES7134-4JB50-0AB0\u003c\/strong\u003e processes signals with a 110ms cycle time per channel and includes an integrated SF LED for group fault diagnostics, ensuring clear status indication. Engineered for reliability in process automation, it features electrical isolation and noise suppression for stable readings in electrically noisy industrial environments. As part of the \u003cstrong\u003eSIMATIC DP\u003c\/strong\u003e system, it integrates seamlessly with PROFIBUS networks for distributed temperature monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2-channel RTD input module.\u003c\/li\u003e\n  \u003cli\u003e15-bit plus sign resolution for precise measurement.\u003c\/li\u003e\n  \u003cli\u003eSupports Pt100, Ni100 (standard and climatic), 150Ω, 300Ω, and 600Ω resistance sensors.\u003c\/li\u003e\n  \u003cli\u003eFast 110ms cycle time per channel.\u003c\/li\u003e\n  \u003cli\u003eIntegrated SF LED for group fault diagnostics.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation and noise suppression for robust operation.\u003c\/li\u003e\n  \u003cli\u003eCompact 15mm width housing for high-density installations.\u003c\/li\u003e\n  \u003cli\u003eSeamless integration with PROFIBUS networks via the SIMATIC DP system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6ES7134-4JB50-0AB0\u003c\/strong\u003e is suitable for applications requiring precise temperature monitoring and control in various industrial sectors. Typical deployments include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHVAC systems for environmental control.\u003c\/li\u003e\n  \u003cli\u003eChemical processing where accurate temperature regulation is critical.\u003c\/li\u003e\n  \u003cli\u003eFood production environments for process quality and safety.\u003c\/li\u003e\n  \u003cli\u003eSystems requiring responsive temperature control loops.\u003c\/li\u003e\n  \u003cli\u003eInstallations with limited cabinet space benefiting from high-density I\/O.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e6ES7134-4JB50-0AB0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input Module (RTD)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eET 200S\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eGERMANY\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eChannels\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003eResistance Temperature Detector (RTD), Resistance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e15-bit plus sign\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Sensor Types\u003c\/td\u003e\n      \u003ctd\u003ePt100, Ni100 (standard and climatic), 150Ω, 300Ω, 600Ω\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCycle Time (per channel)\u003c\/td\u003e\n      \u003ctd\u003e110ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostics\u003c\/td\u003e\n      \u003ctd\u003eSF LED for group fault\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation\u003c\/td\u003e\n      \u003ctd\u003eElectrical isolation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Width\u003c\/td\u003e\n      \u003ctd\u003e15mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003eET 200S distributed I\/O system, SIMATIC DP system\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS (via ET 200S system)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHS Code\u003c\/td\u003e\n      \u003ctd\u003e8537101190\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd\u003e10.5 x 12.5 x 4 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0.24 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, ensure that the power to the ET 200S distributed I\/O system and associated components is completely de-energized to prevent electrical hazards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the \u003cstrong\u003e6ES7134-4JB50-0AB0\u003c\/strong\u003e module onto the designated terminal module within the ET 200S station. Ensure it clicks securely into place.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Connection:\u003c\/strong\u003e Connect the RTD or resistance sensors to the module's terminals according to the wiring diagram for the specific sensor type (e.g., 2-wire, 3-wire, or 4-wire Pt100\/Ni100). Observe correct polarity and terminal assignments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Implement proper grounding and shielding for sensor cables to minimize electrical noise interference, especially in industrial environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route sensor cables away from power cables or other sources of electromagnetic interference to maintain signal integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e After all connections are verified, re-energize the system. Observe the SF LED for any fault indications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Configure the module parameters within the PLC engineering software (e.g., SIMATIC Manager or TIA Portal) to match the connected sensor types and measurement ranges.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695218454891,"sku":"6ES7134-4JB50-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7134-4jb50-0ab0-analog-input-module-1ozkhvfouiy_9b63113d-822d-46f4-82bc-21f8a4faf2e9.jpg?v=1766131019","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7134-4jb50-0ab0-et-200s-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}