{"product_id":"siemens-6es7138-7ec00-0aa0-simatic-et-200isp-power-supply-module","title":"Siemens 6ES7138-7EC00-0AA0 SIMATIC ET 200iSP Power Supply Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7138-7EC00-0AA0 is a power supply module designed for the SIMATIC ET 200iSP distributed I\/O system. This module operates on a wide input voltage range of \u003cstrong\u003e120\/230 V AC\u003c\/strong\u003e, providing versatile power integration for industrial control panels. It is specifically engineered and certified for safe operation in hazardous areas, holding intrinsic safety certifications for both gas and mining environments. Its robust construction ensures reliable power delivery to connected ET 200iSP I\/O modules in critical process automation applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eDesigned for the SIMATIC ET 200iSP distributed I\/O system\u003c\/li\u003e\n    \u003cli\u003eFlexible input voltage of 120\/230 V AC\u003c\/li\u003e\n    \u003cli\u003eCertified for hazardous gas atmospheres: \u003cstrong\u003eEx db eb [ib] IIC T4 Gb\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eCertified for hazardous mining environments: \u003cstrong\u003eEx db eb [ib] I Mb\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProvides intrinsically safe power for connected I\/O modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eOil and Gas production and refining\u003c\/li\u003e\n    \u003cli\u003eChemical and Pharmaceutical processing plants\u003c\/li\u003e\n    \u003cli\u003eUnderground and surface mining operations\u003c\/li\u003e\n    \u003cli\u003eAny industrial process requiring intrinsically safe distributed I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f8fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f8fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6ES7138-7EC00-0AA0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC ET 200iSP\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModule Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply Module\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eInput Voltage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e120\/230 V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExplosion Protection (Gas)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEx db eb [ib] IIC T4 Gb\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExplosion Protection (Mining)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEx db eb [ib] I Mb\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePLM Product Phase\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eActive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.70 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6.00 x 13.65 x 19.00 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85044083\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n    \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: HAZARDOUS AREA INSTALLATION\u003c\/p\u003e\n    \u003cp style=\"margin-bottom: 0;\"\u003eInstallation, modification, and maintenance of this equipment in hazardous locations must be performed only by qualified personnel trained in accordance with local codes and standards (e.g., IEC 60079-14, NEC Articles 500-505). Failure to comply can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely de-energize the control panel and apply Lockout\/Tagout (LOTO) procedures to all incoming power sources. Verify the absence of voltage with a calibrated meter.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eMount Module:\u003c\/strong\u003e Securely mount the 6ES7138-7EC00-0AA0 module onto the designated ET 200iSP terminal block or backplane. Ensure all locking mechanisms are fully engaged to establish a reliable backplane connection.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect AC Power:\u003c\/strong\u003e Connect the 120\/230 V AC line, neutral, and protective earth (PE) conductors to the designated terminals on the module. Use appropriately sized conductors and ensure terminations are torqued to the manufacturer's specification.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eVerify Grounding:\u003c\/strong\u003e Confirm a low-impedance connection from the module's PE terminal to the main system ground bus. Proper grounding is critical for both safety and noise immunity in intrinsically safe circuits.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eFinal Inspection:\u003c\/strong\u003e Before re-energizing, inspect all wiring for correct polarity, secure connections, and proper dress. Ensure the enclosure integrity is maintained to preserve the Ex rating. Remove LOTO devices and apply power according to site procedures.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716763644267,"sku":"6ES7138-7EC00-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7138-7ec00-0aa0-0hmums5pik1_e1197b53-3738-48b5-be3c-a2a5f493a46d.jpg?v=1767088933","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7138-7ec00-0aa0-simatic-et-200isp-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}