{"product_id":"siemens-6es7195-7hb00-0xa0-simatic-et-200m-bus-module","title":"Siemens 6ES7195-7HB00-0XA0 SIMATIC ET 200M Bus Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6ES7195-7HB00-0XA0 is a bus module designed for use within the SIMATIC ET 200M distributed I\/O system. This passive component provides the mechanical and electrical connection for up to \u003cstrong\u003etwo 40 mm wide I\/O modules\u003c\/strong\u003e, integrating them into the ET 200M station's backplane bus. Its design facilitates the removal and insertion of I\/O modules during operation (hot-swapping) without interrupting the system, which is critical for maintaining uptime in continuous process applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eAccommodates two I\/O modules with a width of 40 mm each.\u003c\/li\u003e\n\u003cli\u003eEnables hot-swapping of I\/O modules without system interruption.\u003c\/li\u003e\n\u003cli\u003eProvides a secure mechanical and electrical connection to the ET 200M backplane.\u003c\/li\u003e\n\u003cli\u003eCompact design for efficient use of cabinet space.\u003c\/li\u003e\n\u003cli\u003eDesigned for tool-free handling, simplifying installation and maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eDecentralized automation systems\u003c\/li\u003e\n\u003cli\u003eProcess control and monitoring\u003c\/li\u003e\n\u003cli\u003eManufacturing and assembly lines\u003c\/li\u003e\n\u003cli\u003eMaterial handling and logistics\u003c\/li\u003e\n\u003cli\u003eBuilding automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6ES7195-7HB00-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eET 200M Distributed I\/O System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eBus Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eI\/O Module Capacity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e2 modules (40 mm width each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e9.7 x 9.3 x 6.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Always de-energize the ET 200M station and follow all Lockout\/Tagout (LOTO) procedures before installing or removing bus modules. Failure to disconnect power can result in electric shock, equipment damage, and unintended machine operation.\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003eVerify that the ET 200M station, including the interface module and power supply, is completely de-energized and secured against accidental restart.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003ePosition the bus module on the ET 200M mounting rail. Align the hooks on the rear of the module with the rail profile and press down firmly until it clicks securely into place.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003eInstall adjacent bus modules as required, ensuring they are seated correctly and interlocked with each other to form a continuous backplane bus.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003eOnce the bus modules are installed, insert the corresponding I\/O modules into the slots. Slide them in until they are fully seated and the locking mechanism engages.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003eAfter all modules are installed and wired, remove LOTO devices and restore power to the station according to site procedures. Verify system communication and I\/O status.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695210459499,"sku":"6ES7195-7HB00-0XA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7195-7hb00-0xa0-bus-module-x4abpstwjtz_84fdb4a3-21c8-47ec-a709-902b1a7bf687.jpg?v=1766130814","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7195-7hb00-0xa0-simatic-et-200m-bus-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}