{"product_id":"siemens-6es7214-1bd23-0xb8-simatic-s7-200-smart-cpu-module","title":"Siemens 6ES7214-1BD23-0XB8 SIMATIC S7-200 SMART CPU Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6ES7214-1BD23-0XB8 is a compact CPU module within the SIMATIC S7-200 SMART series, engineered for basic industrial automation and control tasks. This unit integrates a versatile I\/O set, including \u003cstrong\u003e14 digital inputs\u003c\/strong\u003e, \u003cstrong\u003e10 digital outputs\u003c\/strong\u003e, and \u003cstrong\u003e2 analog inputs\u003c\/strong\u003e, making it suitable for small-scale machinery and standalone applications. It features \u003cstrong\u003e12 KB of program memory\u003c\/strong\u003e and \u003cstrong\u003e8 KB of data memory\u003c\/strong\u003e to handle fundamental logic operations. An integrated \u003cstrong\u003eEthernet port\u003c\/strong\u003e provides essential connectivity for programming, monitoring, and networking in modern industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIntegrated 14 Digital Inputs and 10 Digital Outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIncludes 2 onboard Analog Inputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e12 KB Program Memory and 8 KB Data Memory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eBuilt-in Ethernet port for network communication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eCompatible with SIMATIC S7-200 SMART expansion modules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eCompact design for space-constrained control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eOEM machine building\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSmall manufacturing cells\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eConveyor control systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eBuilding automation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSimple motion control tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6ES7214-1BD23-0XB8\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC S7-200 SMART\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProgram Memory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e12 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eData Memory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e8 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCommunication Port\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e14 cm x 6.1 cm x 9.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"border-left: 4px solid #c53030; background-color: #fff5f5; padding: 12px 16px; margin-bottom: 20px;\"\u003e\n  \u003cp style=\"margin: 0; color: #c53030; font-weight: bold;\"\u003eCRITICAL WARNING: Hazardous voltages are present in control cabinets. All installation and maintenance procedures must be performed by qualified personnel using appropriate personal protective equipment (PPE) and following local Lockout\/Tagout (LOTO) safety regulations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003eEnsure the control cabinet is completely de-energized and locked out before beginning installation. Verify the absence of voltage with a properly rated multimeter.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003eSecurely mount the module onto a standard 35mm DIN rail inside the enclosure. Ensure adequate clearance for ventilation and wiring.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003eConnect the 24V DC power supply to the designated terminals. Verify correct polarity to prevent damage to the module.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003eTerminate all digital and analog I\/O wiring at the module's terminal blocks. Use the correct wire gauge and ensure terminals are torqued to the manufacturer's specification. Route signal wires separately from high-voltage power cables.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003eConnect a shielded Ethernet cable to the module's port for network communication. Ensure the cable shield is properly terminated to a chassis ground.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; height: 24px; width: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cdiv\u003eVerify that the module and DIN rail have a low-impedance connection to the main panel's protective earth (PE) ground. After all connections are verified, remove the lockout and re-energize the panel for commissioning.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695216849259,"sku":"6ES7214-1BD23-0XB8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7214-1bd23-0xb8-compact-device-0spbh4g3gra_6d35dfe5-a182-44a4-9430-167353879e47.jpg?v=1766130971","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7214-1bd23-0xb8-simatic-s7-200-smart-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}