{"product_id":"siemens-6es7414-1xg02-0ab0-simatic-s7-400-cpu-module","title":"Siemens 6ES7414-1XG02-0AB0 SIMATIC S7-400 CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6ES7414-1XG02-0AB0\u003c\/strong\u003e is a central processing unit (CPU) specifically engineered for use within the \u003cstrong\u003eSIMATIC S7-400\u003c\/strong\u003e automation system. This CPU, designated as a CPU 414-1, integrates a robust multi-point MPI interface, facilitating seamless communication and integration with various devices and controllers in industrial environments. Equipped with \u003cstrong\u003e128 KB of working memory\u003c\/strong\u003e, the 6ES7414-1XG02-0AB0 delivers reliable performance for demanding production processes, ensuring efficient data processing and communication across the production line. It is a proven choice for applications requiring a balance of performance and durability, suitable for both upgrading existing infrastructure and integrating into new automation projects.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCentral Processing Unit (CPU) for SIMATIC S7-400 systems\u003c\/li\u003e\n  \u003cli\u003eIntegrated multi-point MPI interface\u003c\/li\u003e\n  \u003cli\u003e128 KB working memory\u003c\/li\u003e\n  \u003cli\u003eModular PLC design\u003c\/li\u003e\n  \u003cli\u003eDesigned for reliable performance in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation systems\u003c\/li\u003e\n  \u003cli\u003eDemanding production processes requiring efficient data handling\u003c\/li\u003e\n  \u003cli\u003eLarge-scale automation setups\u003c\/li\u003e\n  \u003cli\u003eUpgrading existing SIMATIC S7-400 infrastructure\u003c\/li\u003e\n  \u003cli\u003eIntegration into new automation projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic S7\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eS7-400\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStandard CPUs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLC Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModular\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWorking Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e128 KB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e25.00 x 18.00 x 5.38 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.03 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, ensure all power to the SIMATIC S7-400 rack is disconnected and secured to prevent accidental re-energization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Insert the CPU module into its designated slot within the S7-400 rack. Ensure it is fully seated and secured using any integrated locking mechanisms or screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the appropriate power supply module to the rack, ensuring correct polarity and secure termination. The CPU draws power from the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPI Interface Connection:\u003c\/strong\u003e Connect the multi-point MPI cable to the designated port on the CPU. Ensure the connection is firm and properly terminated for reliable communication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the S7-400 rack and associated components are properly grounded according to industrial standards to ensure system stability and safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e After physical installation, power on the system and use the appropriate Siemens engineering software (e.g., STEP 7) to configure the CPU and its associated modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables neatly and securely, ensuring they do not interfere with other components or create tripping hazards.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716777341291,"sku":"6ES7414-1XG02-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7414-1xg02-0ab0-x4yyblkn5h4_ca03dc78-9b4f-433f-9ae6-c06def091433.jpg?v=1767089413","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7414-1xg02-0ab0-simatic-s7-400-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}