{"product_id":"siemens-6es7478-2ba00-0ac0-simatic-m7-400-msm478-expansion-module","title":"Siemens 6ES7478-2BA00-0AC0 SIMATIC M7-400 MSM478 Expansion Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6ES7478-2BA00-0AC0\u003c\/strong\u003e is an MSM478 expansion module designed for seamless integration with the SIMATIC M7-400 automation system. This module enhances system capabilities by featuring a built-in hard disk drive with a storage capacity exceeding 500 MB, providing substantial space for process data and critical applications. Additionally, it incorporates a 3.5-inch floppy disk drive with a capacity of 1.44 MB, offering reliable support for legacy data transfer and backup tasks. The \u003cstrong\u003e6ES7478-2BA00-0AC0\u003c\/strong\u003e is engineered for durability, ensuring stable performance in demanding industrial environments. Its robust construction and compatibility with Siemens systems make it a practical solution for expanding storage and data management within production lines or automated processes.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Hard Disk Drive with \u0026gt;500 MB storage capacity\u003c\/li\u003e\n\u003cli\u003eBuilt-in 3.5-inch Floppy Disk Drive with 1.44 MB capacity\u003c\/li\u003e\n\u003cli\u003eDesigned for SIMATIC M7-400 automation systems\u003c\/li\u003e\n\u003cli\u003eRobust construction for industrial environments\u003c\/li\u003e\n\u003cli\u003eSupports legacy data transfer and backup operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpanding local data storage in industrial automation systems.\u003c\/li\u003e\n\u003cli\u003eData management and archiving within production lines.\u003c\/li\u003e\n\u003cli\u003eAutomated processes requiring integrated hard disk and floppy disk capabilities.\u003c\/li\u003e\n\u003cli\u003eSystems needing support for legacy data transfer or backup via floppy disk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC M7-400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMSM478 Expansion Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Disk Drive Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u0026gt;500 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFloppy Disk Drive Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3.5-inch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFloppy Disk Drive Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.44 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e25.00 x 25.00 x 5.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.29 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85389091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, ensure that the SIMATIC M7-400 system and associated power supplies are completely de-energized to prevent electric shock or damage to components.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the expansion module into the designated slot or rack position within the SIMATIC M7-400 system. Ensure all mechanical fasteners are tightened appropriately.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Connections:\u003c\/strong\u003e Connect any necessary data or interface cables to the module. Verify correct polarity and secure connections to prevent signal loss or intermittent operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding of the module and the overall system to minimize electromagnetic interference (EMI) and ensure safe operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower-Up and Verification:\u003c\/strong\u003e After all connections are secure, re-energize the system. Monitor system indicators and perform functional tests to confirm the module is recognized and operating correctly.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eData Transfer:\u003c\/strong\u003e If utilizing the floppy disk drive, ensure proper media insertion and follow system procedures for data transfer or backup.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716771180907,"sku":"6ES7478-2BA00-0AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7478-2ba00-0ac0-cbpo1ax1hft_5cf057d9-3141-4b4e-a2aa-1f380e3bca37.jpg?v=1767089198","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7478-2ba00-0ac0-simatic-m7-400-msm478-expansion-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}