{"product_id":"siemens-6es7647-5em20-0kx0-simatic-box-pc-620-industrial-pc","title":"Siemens 6ES7647-5EM20-0KX0 SIMATIC BOX PC 620 Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-5EM20-0KX0 is an industrial computer from the SIMATIC BOX PC 620 series, designed for robust performance in demanding automation environments. This unit is configured with a \u003cstrong\u003eCeleron 1.2 GHz processor\u003c\/strong\u003e, \u003cstrong\u003e256 MB of SDRAM\u003c\/strong\u003e, and dual \u003cstrong\u003e40 GB hard drives\u003c\/strong\u003e for data storage. It provides extensive connectivity options, including a \u003cstrong\u003e10\/100 Mbit\/s Ethernet port\u003c\/strong\u003e, a \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e, two USB ports, and both PCI and ISA expansion slots. Integrated system monitoring features such as a watchdog timer and temperature monitoring ensure operational reliability. The PC is pre-installed with Windows XP Professional and is powered by a 110\/230V AC industrial power supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eEquipped with an Intel Celeron 1.2 GHz processor.\u003c\/li\u003e\n  \u003cli\u003eOnboard AGP graphics with configurable memory (8\/16\/32 MB).\u003c\/li\u003e\n  \u003cli\u003eIntegrated 10\/100 Mbit\/s Ethernet (RJ45) for network communication.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in PROFIBUS\/MPI interface for field-level device integration.\u003c\/li\u003e\n  \u003cli\u003eFeatures PC Card (PCMCIA Type 3) slot for legacy peripherals.\u003c\/li\u003e\n  \u003cli\u003eIncludes watchdog timer and temperature monitoring for system stability.\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows XP Professional Multilanguage (SP2).\u003c\/li\u003e\n  \u003cli\u003eFlexible expansion with one PCI and one shared ISA\/PCI slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcess control and visualization (HMI\/SCADA).\u003c\/li\u003e\n  \u003cli\u003eData acquisition, logging, and archiving.\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES).\u003c\/li\u003e\n  \u003cli\u003eMachine control and automation gateways.\u003c\/li\u003e\n  \u003cli\u003eIndustrial computing platforms for legacy systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 12px; text-align: left; border-bottom: 1px solid #ccc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 12px; text-align: left; border-bottom: 1px solid #ccc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eCeleron 1.2 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eL2 Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e256 KB SLC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e256 MB SDRAM-133\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e2 x 40 GB (2.5-inch) Hard Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eDVD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eRemovable Media\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e1.44 MB, 3.5-inch Floppy Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eGraphics\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eAGP Onboard, 8\/16\/32 MB (Configurable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e1 x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePROFIBUS\/MPI, 12 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eTTY\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e1 x PCI, 1 x ISA\/PCI (shared)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePC Card Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e1 x PCMCIA Type 3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eSystem Monitoring\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eWatchdog, Temperature Monitoring\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e110\/230V AC Industry Power Pack with NAMUR\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eWindows XP Professional Multilanguage (EN, GER, FR, IT, SP), SP2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e7.05 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e45.0 x 47.5 x 27.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eCountry of Origin (Estimate)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #e53e3e; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation must be performed by qualified personnel only. Failure to adhere to safety procedures can result in equipment damage, severe injury, or death. Always de-energize the control cabinet and follow Lockout\/Tagout (LOTO) procedures before commencing work. Use appropriate Personal Protective Equipment (PPE) and electrostatic discharge (ESD) protection.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely disconnect all power sources to the enclosure where the Box PC will be installed. Verify the absence of voltage using a calibrated multimeter.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Mount the Box PC chassis securely to a stable panel or surface within the control cabinet. Ensure adequate clearance for airflow and cable access. Verify the mounting can support the unit's weight (7.05 kg).\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect the chassis grounding terminal to the cabinet's main protective earth bus using a low-impedance conductor. This is a critical safety connection.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Power and Peripherals:\u003c\/strong\u003e Connect the 110\/230V AC power cable. Connect all required communication cables, such as Ethernet, PROFIBUS\/MPI, and USB devices. Ensure all connectors are fully seated and secured.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections, remove LOTO devices and re-energize the cabinet. Power on the Box PC and confirm that the operating system boots correctly and all peripherals are recognized.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716290933099,"sku":"6ES7647-5EM20-0KX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-5em20-0kx0-btley1qagsy_ef842186-6454-4834-8d11-e9431bdba3d1.jpg?v=1767080340","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7647-5em20-0kx0-simatic-box-pc-620-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}