{"product_id":"siemens-6es7647-6ac35-0hk0-simatic-box-pc-627-industrial-pc","title":"Siemens 6ES7647-6AC35-0HK0 SIMATIC BOX PC 627 Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens 6ES7647-6AC35-0HK0 is a SIMATIC BOX PC 627 industrial computer designed for robust performance in demanding automation environments. It is equipped with a \u003cstrong\u003ePentium M 730 1.6 GHz processor\u003c\/strong\u003e, \u003cstrong\u003e256 MB of DDR2 RAM\u003c\/strong\u003e, and an \u003cstrong\u003e80 GB SATA hard drive\u003c\/strong\u003e. The unit features onboard AGP graphics with shared memory, dual 10\/100 Mbit\/s Ethernet ports for network connectivity, and a variety of standard interfaces including high-current USB 2.0 and serial ports. Integrated industrial-grade features include a watchdog timer, temperature and fan monitoring, and an onboard RAID controller. This model is powered by a \u003cstrong\u003e110\/230V AC industrial power supply\u003c\/strong\u003e and includes two free PCI slots for expansion.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eProcessor: Intel Pentium M 730 (1.6 GHz, 533 MHz FSB, 2 MB SLC)\u003c\/li\u003e\n\u003cli\u003eMemory: 256 MB DDR2 533 SODIMM\u003c\/li\u003e\n\u003cli\u003eStorage: 80 GB SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n\u003cli\u003eGraphics: Onboard AGP with 8-128 MB shared memory\u003c\/li\u003e\n\u003cli\u003eNetworking: Dual 10\/100 Mbit\/s Ethernet RJ45 ports\u003c\/li\u003e\n\u003cli\u003eExpansion: 2 free PCI slots\u003c\/li\u003e\n\u003cli\u003eI\/O: 4x USB 2.0, 1x COM1, 1x COM2 (via PCI card), 1x LPT1 (via PCI card)\u003c\/li\u003e\n\u003cli\u003eMonitoring: Integrated watchdog timer, temperature, and fan monitoring\u003c\/li\u003e\n\u003cli\u003ePower Supply: 110\/230V AC industrial power unit with NAMUR specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) and SCADA visualization\u003c\/li\u003e\n\u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n\u003cli\u003eMachine-level control and processing\u003c\/li\u003e\n\u003cli\u003eIndustrial gateways and communication servers\u003c\/li\u003e\n\u003cli\u003eManufacturing Execution Systems (MES) clients\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px 12px; border-bottom: 2px solid #e2e8f0; background-color: #f7fafc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 10px 12px; border-bottom: 2px solid #e2e8f0; background-color: #f7fafc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eSIMATIC BOX PC 627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e6ES7647-6AC35-0HK0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003ePentium M 730, 1.6 GHz, 533 MHz FSB, 2 MB SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e256 MB DDR2 533 SODIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e80 GBYTE HDD SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eGraphics\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eOnboard AGP, 8-128 MB Shared Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e2 x 10\/100 Mbit\/s Ethernet RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eUSB Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e4 x USB V2.0 (High Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eSerial Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e1 x COM1 (onboard), 1 x COM2 (via PCI card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eParallel Port\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e1 x LPT1 (via PCI card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e2 x PCI (free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eRemovable Media\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e1 x Slot for Compact Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eOnboard Controller\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eRAID Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eMonitoring Features\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eWatchdog, Temperature\/Fan Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e110\/230V AC Industrial Power Unit with NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eIncluded Cable\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003ePower Cable (Europe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eNot Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eProduct Status\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e7.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e45.0 x 47.5 x 27.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border-bottom: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect all power sources and follow Lockout\/Tagout (LOTO) procedures before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control equipment standards and practices.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the PC in a control cabinet or on a panel with adequate ventilation. Ensure sufficient clearance around the unit for airflow to prevent overheating. Verify all mounting hardware is torqued to specification.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis to the main protective earth (PE) ground of the cabinet using a low-impedance connection. Proper grounding is essential for operator safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 110\/230V AC power supply using the provided power cable. Ensure the source voltage matches the power supply rating. Use a dedicated, filtered power source for best performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eI\/O Connections:\u003c\/strong\u003e Connect all peripheral devices, including Ethernet, USB, and serial cables. Use shielded cables for all data communication lines and ensure shields are properly terminated to ground at one end to minimize electrical noise.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e After verifying all connections, restore power to the unit. Proceed with operating system installation and application software configuration as required. Monitor system temperatures and fan operation during initial startup.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716614844779,"sku":"6ES7647-6AC35-0HK0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6ac35-0hk0-ac4goi4nwi0_4a326a5f-205b-483b-8c64-2567bb31dfe1.jpg?v=1767086732","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7647-6ac35-0hk0-simatic-box-pc-627-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}