{"product_id":"siemens-6es7647-6bb00-0ab0-simatic-box-pc-627b-industrial-pc","title":"Siemens 6ES7647-6BB00-0AB0 SIMATIC BOX PC 627B Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6ES7647-6BB00-0AB0, a SIMATIC BOX PC 627B designed for industrial control and visualization applications. This unit is equipped with a \u003cstrong\u003eCeleron M 440 1.86 GHz processor\u003c\/strong\u003e, \u003cstrong\u003e256 MB of DDR2 RAM\u003c\/strong\u003e, and a \u003cstrong\u003e160 GB SATA hard drive\u003c\/strong\u003e. It provides extensive connectivity through dual Gigabit Ethernet ports, four high-current USB 2.0 ports, and an integrated \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e. The system includes an onboard RAID controller for data redundancy and features built-in monitoring for temperature, fans, and system operation via a watchdog timer. This model is configured with a 110\/230V AC industrial power supply and comes pre-installed with Windows XP Professional.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin-top: 10px;\"\u003e\n    \u003cli\u003eOnboard graphics with 128 MB of shared memory.\u003c\/li\u003e\n    \u003cli\u003eIntegrated RAID controller for enhanced data reliability.\u003c\/li\u003e\n    \u003cli\u003eFront-accessible CompactFlash drive slot for removable storage.\u003c\/li\u003e\n    \u003cli\u003eBuilt-in watchdog timer and hardware monitoring for temperature and fans.\u003c\/li\u003e\n    \u003cli\u003eIncludes 2 MB of buffered SRAM for non-volatile data storage.\u003c\/li\u003e\n    \u003cli\u003eIndustrial-grade AC power supply with NAMUR compliance.\u003c\/li\u003e\n    \u003cli\u003eTwo available PCI slots for hardware expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin-top: 10px;\"\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) and SCADA systems\u003c\/li\u003e\n    \u003cli\u003eProcess control and data acquisition\u003c\/li\u003e\n    \u003cli\u003eMachine vision and quality inspection systems\u003c\/li\u003e\n    \u003cli\u003eIndustrial data logging and gateway applications\u003c\/li\u003e\n    \u003cli\u003eAutomation cell control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold; width: 40%;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCeleron M 440 (1.86 GHz, 1 MB L2 Cache, 533 MHz FSB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e256 MB DDR2 667 SODIMM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eBuffered Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 MB Buffered SRAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e160 GB HDD SATA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eGraphics\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOnboard, 128 MB Shared Memory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eEthernet Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 x 10\/100\/1000 Mbit\/s RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eUSB Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 x USB V2.0 (High Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eSerial Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x COM1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePROFIBUS\/MPI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 x PCI (Free)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eRemovable Media\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x CompactFlash Drive Slot (Front-side)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e110\/230V AC Industrial Power Supply with NAMUR\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWindows XP Professional Multi-Language SP2 (DE, EN, FR, SP, IT)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eSystem Monitoring\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWatchdog, Temperature\/Fan Monitoring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eProduct Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e120.5 x 50.5 x 10.0 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n        \u003ctd style=\"padding: 10px; background-color: #f7fafc; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 30px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always use appropriate personal protective equipment (PPE) and follow site-specific lock-out\/tag-out (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        De-energize the control cabinet and verify the absence of voltage before beginning work.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        Select a mounting location that provides adequate clearance for ventilation and cable access as per the unit's specifications.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        Securely mount the Box PC chassis to the panel or mounting plate using all designated mounting points.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        Connect the chassis to the cabinet's protective earth (PE) busbar using a low-impedance conductor.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        Connect the AC power supply cable to a properly rated and protected power source.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        Connect all required peripherals, including Ethernet, USB, serial, and PROFIBUS\/MPI cables. Ensure proper shielding and grounding for communication cables.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: center;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n        After verifying all connections, remove LOTO devices and re-energize the cabinet to commission the system.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716607177067,"sku":"6ES7647-6BB00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6bb00-0ab0-fdlsrfawo4w_fd729f97-6678-41f4-9288-8638a8c14b9b.jpg?v=1767086593","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7647-6bb00-0ab0-simatic-box-pc-627b-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}