{"product_id":"siemens-6es7647-7ba20-0db0-simatic-ipc427c-microbox-pc","title":"Siemens 6ES7647-7BA20-0DB0 SIMATIC IPC427C Microbox PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-7BA20-0DB0 is a SIMATIC IPC427C series Microbox PC designed for compact, fan-less control and visualization tasks in industrial environments. This unit is configured with a \u003cstrong\u003eCeleron M 1.2 GHz processor\u003c\/strong\u003e, \u003cstrong\u003e1 GB of DDR3 RAM\u003c\/strong\u003e, and a \u003cstrong\u003e4 GB replaceable CompactFlash card\u003c\/strong\u003e for storage. It comes pre-installed with the Windows Embedded Standard 2009 operating system, providing a ready-to-deploy platform for various automation applications. This specific model does not include hardware expansion slots or an internal, non-accessible drive.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eProcessor: Celeron M operating at 1.2 GHz with 800 MHz FSB.\u003c\/li\u003e\n\u003cli\u003eMemory: 1 GByte DDR3 1066 SODIMM module.\u003c\/li\u003e\n\u003cli\u003ePrimary Storage: 4 GB externally accessible, replaceable CompactFlash card.\u003c\/li\u003e\n\u003cli\u003eOperating System: Windows Embedded Standard 2009 pre-installed.\u003c\/li\u003e\n\u003cli\u003eDesign: Compact, fan-less Microbox form factor.\u003c\/li\u003e\n\u003cli\u003eExpansion: Configured without hardware expansion capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) visualization tasks.\u003c\/li\u003e\n\u003cli\u003eData logging and acquisition gateways.\u003c\/li\u003e\n\u003cli\u003eCompact PC-based control systems.\u003c\/li\u003e\n\u003cli\u003eCommunication and protocol conversion nodes.\u003c\/li\u003e\n\u003cli\u003eMachine-level data processing and monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6ES7647-7BA20-0DB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC IPC427C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMicrobox PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCeleron M 1.2 GHz, 800 MHz FSB, 1 MByte SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e1 GByte DDR3 1066, SODIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSwappable Drive\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4 GB CompactFlash (replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eInternal Drive\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eHardware Expansion\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows Embedded Standard 2009 (pre-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e3.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e22.90 cm x 15.20 cm x 33.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e84715000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e5A992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation must be performed by qualified personnel only. De-energize and lock out\/tag out all power sources before attempting installation or maintenance. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Select a location within the control cabinet that provides adequate ventilation clearance around the unit's heat sink fins. Ensure the mounting surface (DIN rail or panel) is secure and free from excessive vibration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eGround the Chassis:\u003c\/strong\u003e Connect the chassis grounding terminal to the cabinet's main protective earth (PE) busbar using a low-impedance conductor. A reliable ground connection is essential for noise immunity and safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the specified DC power source to the unit's power input terminals. Verify correct polarity before applying power. Use appropriate wire gauges and secure connections.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect necessary peripherals such as Ethernet cables, USB devices, and display interfaces. Route all signal cables separately from high-voltage power lines to prevent electromagnetic interference.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eInitial Power-Up:\u003c\/strong\u003e After verifying all connections, remove the lockout\/tagout and apply power to the unit. Monitor the system status indicators to confirm a successful boot sequence.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716730843499,"sku":"6ES7647-7BA20-0DB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-7ba20-0db0-ctok3l4jhar_ac5f327b-7b98-4b0f-b996-9cbb65ad64fb.jpg?v=1767088436","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7647-7ba20-0db0-simatic-ipc427c-microbox-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}