{"product_id":"siemens-6es7647-7bk20-0da0-simatic-ipc427c-microbox-pc","title":"Siemens 6ES7647-7BK20-0DA0 SIMATIC IPC427C Microbox PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-7BK20-0DA0 is a SIMATIC IPC427C series industrial microbox PC, engineered for reliable operation in demanding automation environments. This compact unit is powered by an \u003cstrong\u003eIntel Core2 Duo 1.2 GHz processor\u003c\/strong\u003e with an \u003cstrong\u003e800 MHz FSB\u003c\/strong\u003e and a \u003cstrong\u003e3 MB SLC cache\u003c\/strong\u003e, ensuring stable performance for control and monitoring tasks. It is equipped with \u003cstrong\u003e1 GB of DDR3 1066 SODIMM memory\u003c\/strong\u003e for effective multitasking. For industrial networking, the device includes an integrated \u003cstrong\u003ePROFIBUS DP 12\u003c\/strong\u003e interface. Storage is handled by a durable \u003cstrong\u003e50 GB high-endurance SATA Solid-State Drive (SSD)\u003c\/strong\u003e, which comes with Windows Embedded Standard 2009 pre-installed.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eProcessor: Intel Core2 Duo at 1.2 GHz\u003c\/li\u003e\n  \u003cli\u003eMemory: 1 GB DDR3 1066 SODIMM\u003c\/li\u003e\n  \u003cli\u003eStorage: 50 GB High-Endurance SATA SSD\u003c\/li\u003e\n  \u003cli\u003eCommunication: Integrated PROFIBUS DP 12 Interface\u003c\/li\u003e\n  \u003cli\u003eOperating System: Windows Embedded Standard 2009 (Pre-installed)\u003c\/li\u003e\n  \u003cli\u003eCompact, fanless design for industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eProduction Line Control and Monitoring\u003c\/li\u003e\n  \u003cli\u003eData Acquisition and Logging Systems\u003c\/li\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) Applications\u003c\/li\u003e\n  \u003cli\u003eProcess Visualization and SCADA\u003c\/li\u003e\n  \u003cli\u003eEmbedded Control Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 12px; text-align: left; border-bottom: 1px solid #ccc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 12px; text-align: left; border-bottom: 1px solid #ccc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eIntel Core2 Duo 1.2 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eFront Side Bus (FSB)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e800 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eCache\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e3 MB SLC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eMemory\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e1 GB DDR3 1066, SODIMM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eInternal Storage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e50 GB Solid-State Drive (SATA, High Endurance)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eWindows Embedded Standard 2009 (Pre-installed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eIndustrial Communication\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePROFIBUS DP 12\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e3.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e19.0 x 32.5 x 11.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e84715000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003e5A992\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border-bottom: 1px solid #ccc;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely disconnect all power sources to the control panel or machine. Verify the absence of voltage using a calibrated multimeter.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eMount the IPC:\u003c\/strong\u003e Securely mount the Microbox PC to a stable, grounded surface or DIN rail within the control cabinet, ensuring adequate clearance for ventilation and cable access.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eConnect Chassis Ground:\u003c\/strong\u003e Connect the chassis ground terminal of the IPC directly to the main cabinet ground bus using a low-impedance conductor. This is critical for electrical safety and noise immunity.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eConnect Power and I\/O:\u003c\/strong\u003e Connect the DC power supply, PROFIBUS DP, and any other peripheral cables. Ensure all connectors are fully seated and secured. Route signal cables separately from high-voltage power lines to prevent interference.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eSystem Verification:\u003c\/strong\u003e After confirming all connections are correct and secure, remove LOTO devices and re-apply power to the system. Verify the IPC boots correctly and establishes communication on the network.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716460179819,"sku":"6ES7647-7BK20-0DA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-7bk20-0da0-h2gvqpzgyln_4ab3e96f-ce5f-4d8e-8ece-bffeff5e5db8.jpg?v=1767083115","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7647-7bk20-0da0-simatic-ipc427c-microbox-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}