{"product_id":"siemens-6es7647-8ah70-3ba1-simatic-ipc277d-nanobox-pc","title":"Siemens 6ES7647-8AH70-3BA1 SIMATIC IPC277D Nanobox PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6ES7647-8AH70-3BA1\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC IPC277D Nanobox PC\u003c\/strong\u003e designed for industrial automation applications. This compact industrial PC features an \u003cstrong\u003eAtom E660 (1.3 GHz)\u003c\/strong\u003e processor, \u003cstrong\u003e2 GB RAM\u003c\/strong\u003e, and \u003cstrong\u003e8 GB SIMATIC PC CompactFlash\u003c\/strong\u003e for retentivity. It includes a \u003cstrong\u003eDVI-I graphics card connection\u003c\/strong\u003e, \u003cstrong\u003etwo 10\/100\/1000 Mbps Ethernet RJ45 ports\u003c\/strong\u003e, and \u003cstrong\u003efour high-current USB V2.0 ports\u003c\/strong\u003e. Power is supplied via a \u003cstrong\u003e24 V DC industrial power supply\u003c\/strong\u003e. The unit also provides a \u003cstrong\u003eCompact Flash slot\u003c\/strong\u003e and a \u003cstrong\u003eCOM1 RS232 interface\u003c\/strong\u003e, running on \u003cstrong\u003eWES 7 SP1\u003c\/strong\u003e and supporting \u003cstrong\u003eWINAC RTX 2010\u003c\/strong\u003e for embedded control tasks. It is designed for standard mounting rail installation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x DVI-I Graphics Card Connection\u003c\/li\u003e\n\u003cli\u003e2x 10\/100\/1000 Mbps Ethernet RJ45 Ports\u003c\/li\u003e\n\u003cli\u003e4x USB V2.0 Ports (High Current)\u003c\/li\u003e\n\u003cli\u003eCompact Flash Slot\u003c\/li\u003e\n\u003cli\u003e24 V DC Industrial Power Supply\u003c\/li\u003e\n\u003cli\u003eAtom E660 Processor (1.3 GHz)\u003c\/li\u003e\n\u003cli\u003e2 GB RAM\u003c\/li\u003e\n\u003cli\u003e8 GB SIMATIC PC CompactFlash for Retentivity\u003c\/li\u003e\n\u003cli\u003eCOM1: RS232 Interface\u003c\/li\u003e\n\u003cli\u003ePre-installed WES 7 SP1 Operating System\u003c\/li\u003e\n\u003cli\u003eSupports WINAC RTX 2010\u003c\/li\u003e\n\u003cli\u003eDesigned for Standard Mounting Rail Installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial control systems\u003c\/li\u003e\n\u003cli\u003eData acquisition and processing\u003c\/li\u003e\n\u003cli\u003eHuman Machine Interface (HMI) applications\u003c\/li\u003e\n\u003cli\u003eEmbedded automation solutions\u003c\/li\u003e\n\u003cli\u003eDistributed control systems (DCS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Box PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSubrange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIPC277D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNanobox PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePLM Product Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAtom E660 (1.3 GHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRAM\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 GB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRetentivity Storage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 GB SIMATIC PC CompactFlash\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWES 7 SP1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePLC Runtime Support\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWINAC RTX 2010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC Industrial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eGraphics Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x DVI-I\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eEthernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbps RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x V2.0 (High Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSerial Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCOM1: RS232\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eStorage Expansion\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCompact Flash Slot\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStandard Mounting Rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUnknown\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e34.40 x 30.10 x 18.90 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.35 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371099\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDVI-I Port\u003c\/li\u003e\n\u003cli\u003eEthernet RJ45 Ports\u003c\/li\u003e\n\u003cli\u003eUSB V2.0 Ports\u003c\/li\u003e\n\u003cli\u003eCompact Flash Slot\u003c\/li\u003e\n\u003cli\u003eRS232 (COM1) Port\u003c\/li\u003e\n\u003cli\u003eDC Power Input Terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized before beginning installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Nanobox PC onto a standard mounting rail. Ensure adequate clearance for ventilation and cable routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC industrial power supply to the designated power input terminals. Observe correct polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e\n    \u003cul\u003e\n        \u003cli\u003eConnect DVI-I compatible displays to the graphics port.\u003c\/li\u003e\n        \u003cli\u003eConnect Ethernet cables to the RJ45 ports for network communication.\u003c\/li\u003e\n        \u003cli\u003eConnect USB devices to the USB V2.0 ports.\u003c\/li\u003e\n        \u003cli\u003eConnect serial devices to the COM1 RS232 port as required.\u003c\/li\u003e\n        \u003cli\u003eInsert a Compact Flash card into the designated slot if additional storage or system image is needed.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the unit is properly grounded according to local electrical codes and Siemens guidelines to prevent electrical interference and ensure safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables to minimize stress on connectors and avoid interference with other components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e After all connections are verified, re-energize the power supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716740378987,"sku":"6ES7647-8AH70-3BA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-8ah70-3ba1-elmupvoppby_11581df5-65cd-41f1-b4f7-3e0341a7acd0.jpg?v=1767088559","url":"https:\/\/www.plcprotech.com\/products\/siemens-6es7647-8ah70-3ba1-simatic-ipc277d-nanobox-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}